Visual inspection:
1. Are tank [2], hose [6], shut-off valve [8] with pressure gauge [22] and spray wand [7]
with nozzle [41] undamaged?
3D\VSHFLDODWWHQWLRQWRWKHFRQQHFWLRQVEHWZHHQWKHWDQN>@±KRVH>@DQGWKH
KRVH>@±VKXWRIIYDOYH>@DQGWRWKHFRQGLWLRQRIWKHVSUD\ZDQG>@
Function:
2. Activate the pump lever [11]. (Fig. 8)
Ź,QFUHDVLQJSUHVVXUHLVLQGLFDWHGRQWKHSUHVVXUHJDXJH>@)LJVDQG
1. Fasten the carrying strap [1] to the tank. Secure it with the metal pin [12]. (Fig. 2)
2. Attach the eyes [13] on the carrying strap [1] to both sides of the tank.
3. Attach the back cushion [9] to the tank using 2 bolts (outside) and 2 nuts with washers
(inside) [2]. (Figs. 2 and 3)
4. Press the 2 nuts [14] into the carrying handle [3] (for 18 liter devices only). Insert the
carrying handle and screw tight with the 2 screws [15] in the tank [2]. (Fig. 3)
5. Feed the hose [6] through the opening in the lower part of the tank as well as between
the shaft [16] and tank base. Push the hose all the way onto the connecting piece [17].
Tighten the union nut to secure the hose. (Fig. 4)
6. Push the hose [6] all the way onto the connecting piece of the shut-off valve [8]. Tighten
the union nut to secure the hose. (Fig. 4)
7. Screw the spray wand [7] onto the shut-off valve [8]. (Fig. 4)
8. Turn the shaft [16] clockwise until it engages. Insert the pump lever [10] to the required
depth into the shaft [16] (3 positions). (Fig. 5)
3XPSOHYHU>@ZLWKKDQGOHFDQEH¿WWHGRQWKHOHIWRUULJKW
9. Secure the pump lever [10] in the shaft using the retaining clip [18]. (Fig. 5)
10. Push the handle [11] to the required position (A, B, C) into the pump lever [10]. (Fig. 5)
(QVXUHWKDWWKHKDQGOHLVORFNHGLQSODFHLQWKHSXPSOHYHU
Checks
Assembly
Table 1
Technical data
Type of device
RS120
RS125
RS180
RS185
0D[¿OOLQJDPRXQW
12 liters (3.17 US gallons)
18 liters (4.76 US gallons)
Max. spraying pressure
6 bar
Max. operating temperature
40 °C
Net weight
4.5 kg (9.92 lbs)
4.8 kg (10.58 lbs)
Gross weight max.
16.5 kg (9.92 lbs)
22.8 kg (50.27 lbs)
Tank material
Polypropylene
Where device is carried
Back
Technical residual quantity
< 0.25 liters
(0.07 US gallons)
< 0.27 liters
(0.07 US gallons)
0D[YROXPHÀRZ
1.4 l/min (0.53 gal/min) at 6 bar
7KHZKHHOORFN>@FDQEHXVHGWRORFNDQGXQORFNWKHOHYHURQWKHVKXWRIIYDOYH
>@/RFNLQJWKHOHYHU>E@SUHYHQWVXQLQWHQWLRQDOVSUD\LQJ
3. Unlock the wheel lock [23a] and activate the shut-off valve [8]. (Fig. 9)
Ź7KHVKXWRIIYDOYHPXVWRSHQDQGFORVH