Heaters should be connected only to circulating hot water systems where at least 1 gpm water flow 

is expected. They are essentially small unit heaters, and will work on one or two pipe systems, or in a series loop 

where pressure and temperature drop can be tolerated (see capacity charts and piping diagrams). These units are 

not designed for use with steam systems. See bottom paragraph on page 7. These units are not recommended to 

be used with a gravity flow system. Series loop systems do not require scoop or venturi tees.

 

4.

Piping Charts

SYSTEM CONSIDERATIONS

 

NOTE: In an up feed system, unit is located above hot water supply line. In a down feed    

 

system, unit is located below hot water supply line.

For One Pipe System Down Feed, two directional flow tees should be used. They should be spaced 12 

to 18" apart. To better understand directional flow tee installation, refer to page 5.

If directional flow tee's are not available, an adjustable screw operated flow control or circuit setter 

can be placed between the two standard tee's in a one pipe system. 

For consistent response of the reverse acting thermostat, and effective outlet air temperature, the 

average water temperature should not be below 120°F (49°C). Blower motor shuts off at 105°F (41°C) 

and will not operate until water temperature reaches 120°F (49°C).

If utilizing water temperature below 120°F (49°C), the blower will not operate with the self contained

aquastat. An optional low temperature aquastat, 110° to 95°F (43° to 35°C) is available.

Installation should be done with as few fittings as possible. Multiple fittings may cause too much resistance.

FIGURE 4

FIGURE 5

42
84

120

1 GALLON

2 GALLONS
3 GALLONS

.

50

.50
.74

.17'

.8'

1.2'

53

103
127

30.7
30.7
66.8

.22'
.95'
1.5'

AMP

MODEL

MODEL

42

CFM (HIGH SPEED)

MOTOR INFORMATION

FRICTION LOSS (HEAD)

3200
3200
3200

.43'

1.45'
2.97'

.034
.034
.068

115
115
115

WATT

84

VOLTAGE

RPM

120

HP

WIRING DIAGRAM 3

TWIN-FLO

ROOM T'STAT

1

2

115V LINE

CIRCULATOR

ZONE VALVE

W/AUX. SW.

TRANS

LOW VOLT

115/24V

MIN

MAX

T-STAT

(NEUTRAL)

L2

115/1/60

LINE IN

L1

BLUE

(HOT)

SPDT

2 1

3

BLOWER

WHT

MOTOR

BLK

RED

CAT-68254-A

BLUE

OFF

WIRING DIAGRAM C

Содержание Kickspace Series

Страница 1: ...gh a flush mounted louvered front panel Type F is a surface mounted wall unit with the air discharged evenly through a louvered front panel in an upward direction All types have heating elements with...

Страница 2: ...KICKSPACE MODEL 42 FIGURE 1 2 KICKSPACE MODEL 84 FIGURE 2 KICKSPACE MODEL 120 FIGURE 3 Dimensions shown in English and metric DIMENSIONAL DATA...

Страница 3: ...ATION AND SERVICE IT IS RECOMMENDED THAT THIS ACCESS PANEL BE CONSTRUCTED SO ANNUAL CLEANING OF THE BLOWER FAN AND COIL FINS CAN BE EASILY ACCESSIBLE 3 At this location center and cut an opening in th...

Страница 4: ...erated flow control or circuit setter can be placed between the two standard tee s in a one pipe system For consistent response of the reverse acting thermostat and effective outlet air temperature th...

Страница 5: ...allation Figure 8 is a supply installation Figure 9 shows installation for the return side red ring between risers The return tee is installed opposite of the supply tee with the red ring between the...

Страница 6: ...ower turns on check below for possible solutions a Water is not hot enough Check system water temp If radiant system low temperature aquastat may be needed b Water not circulating fast enough Kickspac...

Страница 7: ...eck valve Do not return to bottom drain tapping Operation from steam boiler water is entirely possible as long as supply and return connection is installed be low level of water line on a steam boiler...

Страница 8: ...anship of any installer of the Product This limited warranty is conditional upon a shipment to the Manufacturer of that part of the Product thought to be defective Goods can only be returned with prio...

Отзывы: