Messtechnik optoLAN Скачать руководство пользователя страница 5

opto

LAN

Date:
11/15/11

Manual

Page 5

 3 

Field of application

Transmission of ethernet signals up to 10/100Mbit/s during EMC-

tests

Transmission of ethernet signals over long distances without signal 

loss (up to 100m or more, depending on timing requirements)

Handle ground potential problems

 4 

Maintenance

Recharge batteries after use with the enclosed charger. To prevent a lazy 

battery effect, discharge the devices every 5 times completely by using the 
automatic switch off (Leave the system on, until it turns off automatically). 

Afterwards, charge the devices as usual.

The devices have to be turned off before connecting to the charger. If this 

is disregarded, the system might get damaged!

Fig. 4.1  shows the pinning of the charge connector. Chargers have to be 

connected to pin 2 (+) and pin 4 (GND). An external supply (6…8V, 0.5A) 
can be connected to pin 3 (+) and pin 4 (GND). 

Use only power supplies 

which are certified by mk-messtechnik.

 

Maximum charging 
current is 1 A

Fig. 4.1: Pinning of charge- / buffer connector

Devices must be 
turned off before 
connecting to 
charger, or else the 
system might get 
damaged!

Pinning of charge- / 
buffer connector

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

 

Содержание optoLAN

Страница 1: ...Manual optoLAN Digital optical transmitter for Ethernet 10 100 Mbit signals Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 2: ...Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 3: ...teristics 4 3 Field of application 5 4 Maintenance 5 5 Trouble shooting 7 6 Accessories Options 8 7 Contact 8 Appendix Details and operation A1 Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hil...

Страница 4: ...gital optical system optoLAN can be used to optically transmit ethernet 10 100 Mbit signals Because of the optical transmission the system is very robust against EMS electromagnetic susceptibility It...

Страница 5: ...automatically Afterwards charge the devices as usual The devices have to be turned off before connecting to the charger If this is disregarded the system might get damaged Fig 4 1 shows the pinning of...

Страница 6: ...a longer time Do not use cleaning agents or solvents to clean the devices only use a slightly moistened soft cloth Do not open the devices as there are no parts inside which have to be maintained The...

Страница 7: ...5 125 m Charge batteries Turn on all devices Transmission stops Low battery No optical signal at receiver System turned off Charge batteries Check for light at optical output Replace optical fiber Tu...

Страница 8: ...LWL 2 xm x length in m duplex External batteries BP 60 6V 4Ah Connector cable for BP 60 AK BP Length approx 15cm Charger with connector plugs CH 5 Standard charger Manual MA optoLAN German or english...

Страница 9: ...tical connector FSMA Optical In Out for duplex multimode fiber 62 5 125 m Fig a 2 shows the rear side of the transceivers with RJ45 connector standard ethernet pinning RJ45 plug LAN I O 10 100Mbit s f...

Страница 10: ...ts automatically after a short initialization If the transmission suddenly stops after a long duration of measurement check the Info LED of the transmitter see Fig a 1 If the battery power falls below...

Отзывы: