M=LIGHT Control
Adjust and operate the M=LIGHT LED
8LE-D23_BA_E.docm
05.02.2019
63
/
88
5.4.3.3 Error message in
Auto-Flash Light
und
Flash Light
operating mode
Figure 55: Error message in status bar
Error cause:
I
The incoming Sync signal does NOT correspond to the permissible switch-on duration of the
M=LIGHT LED at preselected intensity (
Power [µs])
.
I
The set value
Pulse delay [µs]
does NOT correspond to the permissible pulse delay to the period of
the Sync signal.
I
Wrong signal polarity set (
Sync Input)
.
Consequence of the error:
I
Sync switch-on processes are NOT performed, which results in bright / dark frame sequences in
the shots.
Preventing errors:
Check if the incoming Sync signal corresponds to the permitted switch-on duration of the
M=LIGHT LED at the pre-selected intensity (
Power [µs])
.
Check whether the
Invert Input
checkmark or the Sync Input Signal are set correctly.
Power [%]
adapt to M=LIGHT LED in tab
Auto Flash Light
.
Check whether
Pulse delay [µs]
is smaller than the period of the Sync signal.
Adjust slide control
Pulse delay [µs]
on tab
Auto Flash Light
/
Flash Light
.
The input signal of the M=LIGHT LED has been adjusted.