![Messoa NCR875-HN5 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/messoa/ncr875-hn5/ncr875-hn5_user-manual_1775580033.webp)
Trigger an Alarm When Ethernet is Lost: set an alarm condition when Ethernet disconnected.
Digital Input: send a signal to the camera to trigger an alarm. Check it to enable this function.
Then, set digital input as “High” or “Low”
Motion Detection: this function is designed to record video once the camera detects a motion
condition. Select “Disable” to disable this function or “Enable” to enable this function.
Sensibility: set sensibility level as “Lowest”, “Low”, “Medium”, “High” or “Highest”. Or input a
value from 0 to 99 in the customized threshold field. Higher number gets higher sensitivity.
Press “Save” to save your settings.
Select a motion detection area by clicking squares displayed on the screen to disable a
detection area. 12 motion detection areas are choices provided. Then press “Save Motion
Window” to save your motion detection area setting.
5.4.3.2 Action
Configure image transfer settings after triggering an alarm.
Select an image transfer method. You could upload the file via FTP server or send via
SMTP. Note that you can only choose one transfer method.
Digital Output: select “OFF” to disable this function or “ON” to enable this function. If select
“ON”, choose an output file’s resolution as “Low” or “High”.
Digital Output
- If you want to set digital output function start, you need to set ON. After that, you need to
set “Active Type” (Low or High) about digital output by the hardware.
Alarm duration
- The alarm time period of digital output.
32
Содержание NCR875-HN5
Страница 1: ...NETWORK CAMERA User s Manual ZS10 0000002G 875 A 5...
Страница 36: ...35...