Defender
™
530
User Manual
Страница 1: ...Defender 530 User Manual...
Страница 2: ...Menu Navigation 2 5 Set Up 2 6 Measurements 2 7 Single 2 8 Burst 2 9 Continuous 2 10 Data Port 3 0 DryCal Pro Software 3 1 Defender Firmware Upgrades 3 2 Annual Maintenance Cal 4 0 Shipping 5 0 Stora...
Страница 3: ...uction Operation Data Port Annual Maintenance and Calibration Shipping Storage Defender 530 Specifications Factory Default Settings Limited Warranty Troubleshooting 2 0 6 0 3 0 7 0 4 0 8 0 5 0 9 0 10...
Страница 4: ...ded to operate your Defender If at any time you have questions regarding its operation please contact Mesa Labs through our Web site drycal mesalabs com or call 973 492 8400 to speak with a member of...
Страница 5: ...3 Data Port Suction Fitting Measuring Cell Pressure Fitting Charging Jack Calibration Label Reset Button Display Anti tamper Label 1 0 3...
Страница 6: ...outlet Initial charging should take about eight 8 hours After the initial charge You may continue to charge your Defender indefinitely simply by leaving it connected to the AC power adapter Be sure t...
Страница 7: ...lated sealed lead acid battery Please note that opening the Defender may damage connections so this procedure should only be used for battery dis posal Procedure Remove five Phillips head screws on th...
Страница 8: ...product name model number and flow range Press the On Off button for 3 seconds to turn your Defender off 2 3 Connections Attaching your Defender to a device Connect device to be calibrated to the app...
Страница 9: ...ighlighted for easy identification 2 5 Menu Navigation Moving through operational menus Use the directional arrows and on the control panel to find your way through the menu When your desired command...
Страница 10: ...ith DryCal Technology MEASURE SETUP 2 6 Set up Customizing the Defender to your needs You can customize your Defender in the SETUP menu Highlight SETUP in the introduc tion screen to enter the Setup M...
Страница 11: ...Hg whereas standardizing temperature is an user settable value set at Std To in the Units sub menu Choose the number of measurements in the average from 1 to 100 If you wish to incorporate a time dela...
Страница 12: ...temperature by setting Std To to a value from 0 to 50 deg C or 32 to122 deg F Std To effects the flow rate measurement only when the reading Type in the Reading sub menu is set to standardized Std Ti...
Страница 13: ...KC to operate with SKC CalCheck Interface Magnification Controls the amount of data on the display Select Zoom to view only flow measure ments in larger font or select Detail to simultaneously view fl...
Страница 14: ...e to misuse or accidental damage Please note that a leak test is not a substitute for a comprehensive examination of the unit s overall per formance and it does not ensure that your Defender is operat...
Страница 15: ...t of Range warning appears Immediately lower or disconnect the flow When the flow is within the proper range select RESET to clear your Defender s last measurement About This screen provides basic inf...
Страница 16: ...for 1 second to turn on your Defender When first turned on your Defender displays an opening screen showing the product name model number and flow range Press the On Off button for 3 seconds to turn...
Страница 17: ...urement This setting functions in the same manner as SINGLE but measurements continue automatically until the preset number of measurements has been made Operation then ceases and the last reading and...
Страница 18: ...to 100 by accessing the SETUP menu In Continuous or Burst mode select PAUSE to terminate the current flow measurement but to leave the average flow mea surement and previous flow measurement on the s...
Страница 19: ...igured table The data can be exported to se lectable Microsoft office environment To run DryCal Pro you must have Windows XP or 7 Microsoft Excel 2003 and up and a RS232 port or if your PC does not ha...
Страница 20: ...17025 accredited laboratory such as our Butler NJ facil ity to ensure its measurement integrity For the ultimate in Defender maintenance and to take advantage of any available software and mechanical...
Страница 21: ...by telephone at 973 492 8400 Our web site address is www mesalabs com Note Mesa Labs will not evaluate or service your instrument without an RMA number If we find the issues you have identified are ap...
Страница 22: ...o its AC power adapter charger while in storage If your Defender cannot be attached to its AC power adapter charger while in storage please do the following Fully charge it before extended storage If...
Страница 23: ...nits cc min mL min L min cf min Standardized Flow Units scc min smL min sL min scf min Pressure Units mmHg PSI kPa Temperature Units C F Basics Dimensions H x W x D 5 5 x 6 x 3 in 140 x 150 x 75 mm We...
Страница 24: ...or Pressure Operating Pressure Absolute 15 PSI Operating Temperature 0 50 C Ambient Humidity 0 70 non condensing Storage Temperature 0 70 C Warranty 1 year battery 6 months DryCal Pro Software DryCal...
Страница 25: ...h the following Default settings from the factory Reading Type Vol Number in Average 10 Time Between 0 Flow Units cc min Pressure Units mmHg Temperature Units C Standardizing Temp 21 1 C Measurement M...
Страница 26: ...ories Inc shall have no liability to repair or replace any Mesa Laboratories Inc product 1 That has been damaged following sale including but not limited to damage resulting from improper electrical v...
Страница 27: ...ender for pres sure sources or to the suction port for verifying suction pumps The unused port should be at atmospheric pressure with any cap or plug removed If you are calibrating a gas that requires...
Страница 28: ...dead volume Dead volume is the gas volume between a flow generator and the instrument taking the measurement Since gas is compressible this gas can act as a spring between the flow source and the meas...
Страница 29: ...ou We strive to provide the closest NIST traceable legal defensibility of any flow calibration equipment manufacturer and we actively maintain our NV LAP NIST ISO 17025 laboratory accreditation in ord...