7I37 10
OPERATION
OUTPUT CHARACTERISTICS
AC LOADS
The 7I37 can drive low voltage (up to 24VAC) AC loads by series connecting two
outputs. For example a 24V AC switch could be created by connecting OBIT0+ to OBIT1+
and using OBIT0- and OBIT1- as the output leads. An output snubber circuits should be
used across inductive loads. For AC switching, both output bits should change at the same
time