4I33 8
4I33 OPERATION
CONFIGURATION
If not used in PNP mode, an on card EEPROM is used to store the 4I33
configuration parameters. A supplied DOS program: RSET8019 is used to change
these parameters.
CONFIGURATION OPTIONS
RSET8019 allows setting of the following options:
I/O ADDRESS
200H 220H 240H 260H 280H 2A0H 2C0H 2E0H
300H 320H 340H 360H 380H 3A0H 3C0H 3E0H
Note that some of these addresses will be unavailable due to conflicts with
existing peripherals.
IRQ
2/9
3
4
5
10
11
12
15
MEDIA
10Base2
10Base5
10BaseT
Auto
If MESAs external panel mount transceiver (MAU) is used, the 10 Base2 mode
should be selected. This is because the MAU gets its isolated transceiver power from
the 4I33s DC-DC converter and 10Base5 mode will disable on DC-DC converter.