RX
RED4-RL
8 conductors shielded cable
5
6
BROWN
WHITE
PINK
YELLOW
GREY
GREEN
D1
2
1
3
4
D2
E
D
M
xternal
evice
onitor
K2
I
=
max
0,7A
K1
OSSD1
MUTE1
Control devices of the
function.
: when activated, temporarely, they
neutralize the light-curtain protective action.
MUTING
WARNING
OSSD2
MUTE2
5m standard
cable length
8 CONDUCTORS M12
FEMALE CONNECTOR
F1
F2
Fig.16
P.N. : the E.D.M. function works
only if loads K1, K2, … Kn are
with forced interlocked contacts
operation. E.D.M. must be used to
reach the safety caegory declared.
I
=
max
0,7A
INTERLOCK
PUSH-BUTTON
START/RESTART
F1=F2= fuses of a higher value
than the current sinking
into the load (suggested)
D1=D2= rectifier diodes to suppress
“spikes” generated by t he an
inductive load that reduced
life of the output switches of
the light-curtain (recommended)
+
24V
POWER SUPPLY
24Vdc +/- 10%
SCR
SCR = extra-voltages discharger to
suppress possible high energy
discharge (recommended)
NC SWITCH
K1
NC SWITCH
K2
NC SWITCH
Kn
0V
BLUE
SHIELD
RED
7
8
{
RX
RED2-RL
D1
D2
K1
K2
8 conductors shielded cable
5
6
BROWN
WHITE
PINK
YELLOW
GREY
GREEN
2
1
SW1
SW2
SW1
SW2
I
max
= 0,7A
I
max
= 0,7A
V
max
= 40Vdc/ac
V
max
= 40Vdc/ac
5m standard
cable length
F1
F2
F1=F2= fuses of a higher value
than the current sinking
into the load (suggested)
Fig.15
D1=D2= rectifier diodes to suppress
“spike” generated by the an
inductive load that reduced
life of the output switches of
the light-curtain (recommended)
8 CONDUCTORS M12
FEMALE CONNECTOR
SCR = extra-voltages discharger to
suppress possible high energy
discharge (recommended)
3
4
E
D
M
xternal
evice
onitor
If the functions E.D.M. and START-RESTART
are not used, connect the conductor
(4) to the “0V” of power supply
yellow
red/shield (8)
INTERLOCK
PUSH-BUTTON
START/RESTART
NC SWITCH
K1
NC SWITCH
K2
NC SWITCH
Kn
+
24V
POWER SUPPLY
24Vdc +/- 10%
SCR
0V
P.N. : the E.D.M. function works
only if loads K1, K2, … Kn are
with forced interlocked contacts
operation. E.D.M. must be used to
reach the safety caegory declared.
7
8
BLUE
RED
SHIELD
{
ELECTRICAL CONNECTIONS - RX
12.1
MUTING :
MERLINO elettronica s.a.s. di Meroni N.
Via Como, 33/A - 20851 Lissone - MB
E-mail: [email protected]
Web-site: www.merlinoelettronica.it
Pag. 13
DESIGN AND MANUFACTURE
OF ELECTRONIC EQUIPMENT
MERLINO elettronica s.a.s. di Meroni N.
Via Como, 33/A - 20851 Lissone - MB
E-mail: [email protected]
Web-site: www.merlinoelettronica.it
For the
Laser guard model, the “Neutralization” or “Muting” function is also previded, that is the possibility of being able to suspend in temporary way
its own protecting function. That it means that when the two dedicated inputs are simultaneously activated (within a maximum time of 0,8 second) putting
separately in short-circuit the PINK and GRAY conductors to the “0V” of power supply (RED conductor and Shield), the Laser Guard surveillance action comes
temporarely neutralized, allowing that the Laser beam can be darkened without that the output signal switching devices (OSSDs) switch to the inactive OFF state. A
red color blinking signaler, situated on the top head of the “RX” section (Pag.8), shows the activation of the Muting function. In the event of the two dedicated muting
inputs are not simultaneously activated, or however with a time delay more than 0,8 second, the RED4-RL switches into the block state opening the output signal
switching devices (OSSDs) and signaling it as the “D” case of the diagnostic table of Pag 8. Make attention using this function as it could generate potentially
dangerous situations. Adopt a visual and/or acoustic additional external signaler to indicate in unequivocal way the inactivity state of the Barrier to activated Muting.
“RED4-RL”
: disconnect the
green cable (3) from the
"0V" of the power supply (8)
to exclude Front and Rear
sensors of the device
BLANKING
BLANKING
BLANKING
: disconnect the
green cable (3) from the
"0V" of the power supply (8)
to exclude Front and Rear
sensors of the device
BLANKING
EDM/STR-RSTR
EDM/STR-RSTR
If the functions E.D.M. and START-RESTART
are not used, connect the conductor
(4) to the “0V” of power supply
yellow
red/shield (8)