TECHNICAL CHARACTERISTICS

MERLINO elettronica s.a.s. di Meroni N.
Via Como, 33/A - 20851 Lissone - MB
E-mail: [email protected]
Web-site: www.merlinoelettronica.it

Pag. 11

DESIGN AND MANUFACTURE
OF ELECTRONIC EQUIPMENT

MERLINO elettronica s.a.s. di Meroni N.
Via Como, 33/A - 20851 Lissone - MB
E-mail: [email protected]
Web-site: www.merlinoelettronica.it

PROTECTED HEIGHT (PH)

12mm

DETECTION CAPABILITY (DC)

>14mm

WORKING RANGE
RESPONSE TIME

8msec

TX INDICATOR

OSSDs TYPES

PROTECTION FEATURES

POLARITY INVERSION

SUPPLY VOLTAGE

24Vdc 10%

12Vdc on request

±

CURRENT CONSUMPTION

TX 70mA

RX 50mA

WORKING TEMPERATURE

0 to + 50°C

UMIDITY

25

85%

÷

FASTENING MEANS

4 x M5 THREADED STUDS

PROTECTION DEGREE

IP54

1

6 meters

÷

RX INDICATOR

RED LASER BEAM = ACTIVE EMISSION

RED=ALARM

GREEN=ALERT

YELLOW=BLOCK

ORANGE=BLANKING F/R

TOTAL LENGHT (TL)

TX=167mm - RX=167mm

2 VOLTAGE

SWITCHES 0,7A @ 40Vdc/ac

FREE

EMISSION

RED LASER

= 650 nm / P=1mW

OUTPUT CONNECTION

5 METERS CABLE LENGHT M12 CONNECTOR TX = 5 POLE - RX = 8 POLE

HOUSING

ANODIZED ALUMINIUM - CROSS SECTION 53 x 103 mm

AVAILABLE FUNCTIONS

E

D

M

XTERNAL

EVICE

ONITOR - START/RESTART INTERLOCK - BLANKING

PROTECTED HEIGHT (PH)

12mm

DETECTION CAPABILITY (DC)

>14mm

WORKING RANGE
RESPONSE TIME

8msec

TX INDICATOR

OSSDs TYPES

PROTECTION FEATURES

POLARITY INVERSION - OUTPUT SHORT CIRCUIT - CURRENT THRESHOLD

SUPPLY VOLTAGE

24Vdc 10%

12Vdc on request

±

CURRENT CONSUMPTION

TX 70mA

RX 50mA

WORKING TEMPERATURE

0 to + 50°C

UMIDITY

25

85%

÷

FASTENING MEANS

4 x M5 THREADED STUDS

PROTECTION DEGREE

IP54

1

6 meters

÷

RX INDICATOR

RED LASER BEAM = ACTIVE EMISSION

RED=ALARM

GREEN=ALERT

YELLOW=BLOCK

BLK. RED= MUTING

ORANGE=BLANKING F/R

TOTAL LENGHT (TH)

TX=167mm - RX=167mm

2 PNP OPEN COLLECTORS 0,7A @ 40Vdc/ac

MAX. LOAD CAPACITY

0,1 uF

EMISSION

RED LASER

= 650 nm / P=1mW

OUTPUT CONNECTION

5 METERS CABLE LENGHT M12 CONNECTOR TX = 5 POLE - RX = 8 POLE

HOUSING

ANODIZED ALUMINIUM - CROSS SECTION 53 x 103 mm

AVAILABLE FUNCTIONS

E

D

M

XTERNAL EVICE

ONITOR - START/RESTART INTERLOCK - MUTING - BLANKING

RED2-RL

TYPE2 - SIL1 - SILCL1 - PLc

NUMBER OF BEAMS

4

RED4-RL

TIPO4 - SIL3 - SILCL3 - PLe

MISU-RED-RL-UK-1.0

Содержание RED-RL Series

Страница 1: ...IC PROTECTIVE DEVICE AOPD AT LASER EMISSION PREFACE This manual provides the user and or installer with the information required for correct use of the RED RL device in the application for which it wa...

Страница 2: ...15 PAG 16 TX RX 1 Preface 2 Contents 3 Warranty Attendance Supplied material 4 Legend Verifying the protected area 5 Introduction Installation 6 Chosen of the Device Precautions 7 Available functions...

Страница 3: ...istance centres not authorised by the manufacturer The resulting costs and risks associated with transport packing and labour are the responsibility of the purchaser The replacement of the device and...

Страница 4: ...covered by this manual mitter section of the RED RL light guard emitting LASER radiation with a wavelength of eceiver section of the RED RL light guard acting as a sensor and command and control devi...

Страница 5: ...TX and Receiver RX are perfectly parallel and fixed using the supplied means at the working distance specified when ordering and reported on the rating plate under the heading Working Distance Keep th...

Страница 6: ...sensor units are correctly fixed using special supports in electrically insulating material Connection of other equipment to the power source used to power the RED RL device is not recommended This co...

Страница 7: ...o the inside EDM circuit Between this conductor and ground 0V of power supply has to be in series connected the normally open switches of the external output load devices thus from being able to test...

Страница 8: ...power on RED4 RL model only D LEDs STATUS CASE BLINKING ON OFF BLK ALT RUN OFF MUTE E F G H OFF OFF ON BLK ALT RUN OFF MUTE OFF ON OFF BLK ALT RUN OFF MUTE OFF OFF ON BLK ALT RUN BLINKING MUTE BLINKI...

Страница 9: ...hite Green Yellow Brown Marrone SW1 SW2 BLANKING R F EDM STR RSTR 5 Grigio 6 Rosa 7 Blu 8 Rosso Grey Pink Blue Red SW1 SW2 24V GND Connect Shield to GND Collegare lo Schermo a GND If the functions E D...

Страница 10: ...point for vertically installed light curtains with a detection capability of no more than 40 mm are given below is the safe distance to be respected when installing the device is a constant establish...

Страница 11: ...ON 5 METERS CABLE LENGHT M12 CONNECTOR TX 5 POLE RX 8 POLE HOUSING ANODIZED ALUMINIUM CROSS SECTION 53 x 103 mm AVAILABLE FUNCTIONS E D M XTERNAL EVICE ONITOR START RESTART INTERLOCK BLANKING PROTECTE...

Страница 12: ...SW2 MUTE2 SW2 24V GND GND RED2 RL 1 2 3 5 4 Male plug Female socket Female socket Male plug If the function TEST is not used short circuit the conductors 4 5 and connect them to the 0V of power supply...

Страница 13: ...to reach the safety caegory declared 7 8 BLUE RED SHIELD ELECTRICAL CONNECTIONS RX 12 1 MUTING MERLINO elettronica s a s di Meroni N Via Como 33 A 20851 Lissone MB E mail merlinoelettronica tiscali it...

Страница 14: ...merlinoelettronica tiscali it Web site www merlinoelettronica it 167 56 56 53 53 30 51 30 50 66 30 20 167 51 50 66 20 50 4 x M5 45 4 x M5 45 50 Pag 14 DESIGN AND MANUFACTURE OF ELECTRONIC EQUIPMENT M...

Страница 15: ...at with the machine stationary and power to the laser guard on no obstacle in the protected area the green indicator is lit with the machine stationary and power to the on in the presence of an obsta...

Отзывы: