37
OPERATION
AND MAINTENANCE
» MAINT MANUAL RELEASE
MAINTENANCE
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• Inspection and service should always be performed anytime a malfunction is
observed or suspected.
• When servicing, please do some “house cleaning” of the operator and the area
around the operator. Pick up any debris in the area. Clean the operator as needed.
• It is suggested that while at the site voltage readings be taken at the operator.
Using a Digital Voltmeter, verify that the incoming voltage to the operator it is
within ten percent of the operator’s rating.
• Refer to FORCE ADJUSTMENT section for instructions to adjust the gate force.
CHECK AT LEAST ONCE EVERY
DESCRIPTION
TASK
MONTH
6 MONTHS
3 YEARS
External Entrapment Protection System
Check and test for proper operation
X
Manual Release
Check and test for proper operation
X
Gate
Inspect for wear or damage
X
Accessories
Check all for proper operation
X
Electrical
Inspect all wire connections
X
Mounting Hardware
Check for tightness
X
Batteries
Replace
X
Operator
Inspect for wear or damage
X
Warning Signs
Make sure they are present
X
Disconnect power before servicing.
MANUAL RELEASE
In case of a power failure, the operator can be disengaged from the gate. With an
operator, the release action may sometimes feel stiff/jerky, which is normal and has
no effect on function.
RELEASE
Insert the key into the lock.
Turn the key clockwise 180°.
Turn the release lever 180°.
Operator is in manual mode and the gate can be opened and closed manually.
ENGAGE
Turn the release lever 180°. This engages the motor.
Turn the key counter-clockwise 180°. This locks the release lever.
Remove the key and store in a safe place.
The operator is now engaged.
INSTALL SAFETY LABEL FOR MANUAL RELEASE ADJACENT TO MECHANISM
1
2
3
1
2
3
1
2
3
1
2
3