background image

REMOTE CONTROL

Once the remote control has been programmed operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open 

the gate. During the open cycle another activation of the remote control will stop the 

gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will 

close the gate.

OPERATION

 

AND MAINTENANCE

 » REMOTE CONTROL 

CLOSE

EDGE

OPEN

PHOTO

OPEN/EGE

PHOTO

CLOSE

PHOTO

R1

LEARN

XMITTER

L1

Ø14GPØ89ØE

Ø14LGØ89ØE

Ø14SKØ89ØE

P2

J1

J19

S1

SAVE

MAGLOCK

MODE

EDGE

PHOTO

OFF

OFF

SINGLE

NO

NO

ON

ON

DUAL

NC

NC

LEARN

XMITTER

S8

1   2   3   4   

5

O

N

2

1

SWITCHED

ACCESSORY

POWER

24V

OVLD

36

INSTALLATION TIPS CONTINUED

Before powering up the MGL400-24.
•  Install gate and opener in the open position.
•  Disengage the opener (using the manual release) and operate gate manually to ensure gate opens and closes smoothly without any interference with mounting hardware.
•  Complete full open and close cycle and ensure piston does not bottom out in either full open/close position.
•  Adjust mounting hardware as necessary to eliminate interference and ensure proper piston travel.
•  Repeat above steps and verify proper installation.
•  Close the gate (recommended programming limits from closed position).
•  Re-engage the opener (using the manual release).
•  Proceed with programming limits.
•  Press program limit button. Open limit light flashes. Installer must program open limit first.

 

INSTALLATION

 STEPS CONTINUED

  

Содержание MGL400-24

Страница 1: ...ial Secondary Arm Serial Control Box Installation Date The MGL400 24 is intended for use with vehicular swing gates For residential applications only refer to page 2 for more details DESIGNED FOR PROF...

Страница 2: ......

Страница 3: ...view of Typical Installation 9 10 Check Your Gate 11 Mounting Options 11 Manual Release 12 Determine Position of the Pull to Open Bracket 12 Assemble Gate Post Bracket Pull to Open 13 Attach Brackets...

Страница 4: ...ing As your primary type of entrapment protection you must provide Type A inherent built into the operator entrapment sensing and we highly recommend at least one of the following as your secondary en...

Страница 5: ...over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use 9 The Stop and or Reset if provided separa...

Страница 6: ...sured in the horizontal plane parallel to the roadway between a fixed stationary object nearest the roadway such as a gate support post and the gate frame when the gate is in either the fully open pos...

Страница 7: ...should be on a separate fused line of adequate capacity ALL electrical connections MUST be made by a qualified individual DO NOT install ANY wiring or attempt to run the operator without consulting th...

Страница 8: ...ONLY when the gate is not moving KEEP GATES PROPERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to gate hardware The entrance is for vehicles ONLY Pedestrians MUST...

Страница 9: ...s Protection Fuse Battery ATC 20A RESET 10 25 4 cm 14 35 6 cm 6 15 2 cm 36 3 92 1 cm 475 DIA 1 2 cm DIA 4 5 11 2 cm 25 0 635 cm 37 4 95 cm 53 5 136 cm 4 10 2 cm Standard Control Box 433 MHz 1 Antenna...

Страница 10: ...e house with appropriate wiring to the gate controller and battery some distance away Follow the tables for minimum recommended conductor sizes for different distances Cable length Conductor size mm2...

Страница 11: ...th Batteries Antenna PVC Conduit not provided to protect the low voltage wire from lawn mowers and string trimmers Hinge Earth Ground Installation Optional Photoelectric Sensors Operator Cable Operato...

Страница 12: ...wn mowers and string trimmers Photoelectric Sensors Extension Cable Photoelectric Sensors Junction Box Gate 2 NOTE One or more non contact sensors shall be located where the risk of entrapment or obst...

Страница 13: ...ON CHECK YOUR GATE MOUNTING OPTIONS CHECK YOUR GATE MOUNTING OPTIONS Mounting locations vary depending on type and style of your gate Minimum distance from the ground should not be less than 10 2 cm f...

Страница 14: ...is now in manual mode MANUAL RELEASE 1 2 Key Release Lever 1 2 The Pull to Open bracket can be assembled to work on a Left Hand or a Right Hand gate Review the gate types and select the type of insta...

Страница 15: ...st bracket ASSEMBLE GATE POST BRACKET PULL TO OPEN Insert the bolt through both brackets and secure with washer lock washer and nut 1 2 Lock Washer Nut Hex Bolt 3 8 Pull to open Bracket Post Bracket W...

Страница 16: ...8 cm Operator Hinge Point 7 18 cm X X Close the gate Close the gate Place the template provided on the back page of this manual under the center of the gate hinge point Place the measuring tape under...

Страница 17: ...sition Temporarily secure gate post bracket with clamp The gate operator arm must be level 2 1 2 4 INSTALLATION POSITION GATE OPERATOR ON GATE 5 Hex Bolt 3 8 Lock Washer Nut Washer Align the Pull to O...

Страница 18: ...e the gate 1 1 2 2 3 3 1 2 1 2 1 3 cm Do not allow piston to fully extend or fully retract 3 SECURE POST BRACKET TO GATE POST The gate operator arm must be level Drill adequate holes in the gate post...

Страница 19: ...a Angle Iron Wood Flat Bar WARNING SIGN PLACEMENT Moving Gate Can Cause Injury or Death KEEP CLEAR Gate may move at any time without prior warning Do not let children operate the gate or play in the g...

Страница 20: ...nd coaxial connector Select mounting holes and knock out using a screwdriver and hammer Remove screws and open the control box Loosen screws to remove the control board and mounting bracket 1 3 4 5 2...

Страница 21: ...de of the control box and not pinched Attach the antenna Ensure the connection to the control box is tight and a good water seal Reinstall the batteries control board alarm and reset button NOTE do no...

Страница 22: ...tom of the control box Select hole in bottom of the control box to be used for the operator cable CONNECT THE GATE OPERATOR GATE 1 TO THE CONTROL BOX Insert the watertight connector into the bottom of...

Страница 23: ...n mount the control box on the opposite side but connect the operator closest to the control box to the Gate 2 connector and the operator on the opposite side to the Gate 1 connector NOTE The gate wit...

Страница 24: ...s with the table shown on page 8 cable that is too thin can cause gate to be inoperable P1 F2 F6 U4 MAX C13 C4 GATE 2 GATE 1 GRN WHT YEL BLU RED BRN GRN WHT YEL BLU RED BRN D15 C2 R4 R9 R196 24 VAC SO...

Страница 25: ...r ate the gate or play in the gate area This entra nce is for vehic les only Pede stria ns mus t use sepa rate entra nce Gate Operator Gate 2 Extension Cable Within 5 1 5 m Junction Box Screws 4 WIRIN...

Страница 26: ...hite Yellow Blue Red Special Connector Terminal Block Connector Extension Cable Operator Cable Brown Brown Green Green White White Yellow Yellow Blue Blue Red Red 24 Insert wires from extension cable...

Страница 27: ...CESSORY POWER MAGLOCK ALARM GATE 1 J4 D15 C2 MOV2 C2 R4 24 VAC SOLAR INPUT J4 Ground Screw Control Box 12 Gauge Wire Earth Ground Installation Optional 3 0 9 m 8 2 4 m WIRING EARTH GROUND ROD INSTALLA...

Страница 28: ...eyes EDGE INPUT Set switch S1 4 to the following settings N O Edge Active Close 8 2K 10K Edge N O dry contact edge N C Edge Active Open N C dry contact edge NOTE Monitored Edges should be set in the N...

Страница 29: ...LOSE LIMIT LEARN LIMITS DIAGNOSTIC GATE 1 SET CLOSE DIAGNOSTIC GATE 1 SET CLOSE DIAGNOSTIC GATE 1 FORCE GATE 2 SET CLOSE LIMIT LE LIMIT FORCE GATE 2 SET CLOSE LIMIT LE LIMIT SET OPEN LIMIT N T SET OPE...

Страница 30: ...s to blink repeat programming If the problem continues see Troubleshooting section Test the limits by pressing the SBC to open and close the gate DUAL GATE LEFT SIDE PRIMARY OPERATOR Press the GATE 2...

Страница 31: ...S button 4 5 6 7 8 9 DUAL GATE RIGHT SIDE PRIMARY OPERATOR The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking programming is now complete If the SET OPEN LIMIT LED c...

Страница 32: ...ontrol SBC button on the control board open and then close the gate If the gate stops or reverses before reaching the fully open or closed position increase the force by turning the force control slig...

Страница 33: ...s All previous codes are now erased Remote Control LEARN XMITTER Button PROGRAMMING REMOTE CONTROLS KEYLESS ENTRY ERASE ALL CODES TEST 2 1 1 2 1 K5 LEARN XMITTER R1 R1 1 2 Remote Control LEARN XMITTER...

Страница 34: ...rd goes into Sleep Mode Remove only if remotely mounted Stop button is added OPEN Opens only or reverses a closing gate SBC SINGLE BUTTON CONTROL INPUT This input will command the gate to OPEN STOP CL...

Страница 35: ...ber MGL400 BOX to enclose safety electronics OPEN SAFETY EDGE PHOTOELECTRIC SENSOR ENTRAPMENT If an Open Edge device or a Retro Reflective Photoelectric Sensor has been connected to Terminal P8 then t...

Страница 36: ...4V MAGLOCK C NC NO MAGLOCK C NC NO SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION The following devices are acceptable for Safety Accessories for secondary entrapment protection These devices...

Страница 37: ...is supply connection draws power from the unit continuously and only devices that require power to operate the unit should be drawn from this area Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 14GP 89...

Страница 38: ...00 24 Install gate and opener in the open position Disengage the opener using the manual release and operate gate manually to ensure gate opens and closes smoothly without any interference with mounti...

Страница 39: ...per operation X Manual Release Check and test for proper operation X Gate Inspect for wear or damage X Accessories Check all for proper operation X Electrical Inspect all wire connections X Mounting H...

Страница 40: ...K MODE EDGE PHOTO OFF OFF SINGLE NO NO ON ON DUAL NC NC LEARN XMITTER S8 1 2 3 4 5 O N 2 1 14 13 12 20 11 10 2 3 5 4 6 22 7 8 18 17 26 19 1 9 23 24 25 15 16 21 ITEM DESCRIPTION FUNCTION 1 Connector P1...

Страница 41: ...LEARN LIMITS DIAGNOSTIC GATE 1 J4 S AVE MAGLOCK MODE EDGE PHO TO OFF OFF SINGLE NO NO ON ON DUAL NC NC LEARN XMITTER S8 1 2 3 4 5 O N 2 1 ANTENNA CONNECTION YELLOW GREEN OR OPTIONAL EARTH GROUND WIRE...

Страница 42: ...from obstruction 1 Constant Open Command Check LED s Clear all Open Safety devices from obstruction 2 Timer to Close not set See Timer to Close section for adjustment instructions 3 Accessory device...

Страница 43: ...w approximately 6 35 mm 1 4 of additional travel in both directions Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 14GP 89 E 14LG 89 E 14SK 89 E K6 K2 F3 10A 32V D1 OPEN EDGE PHO TO OPEN PHO TO CLOSE P...

Страница 44: ...442SA Release Lever 1 2 41ASWG 438SA Motor with Limit 1 Switch Harness 3 41ASWG 0014SA Rear Connector 1 4 41ASWG 489 Cable 24 V with Connector 1 Not Shown 41ASWG 0119 Release Key 1 K77 19130 Hardware...

Страница 45: ...With key ring and fastening strip LOCK LIGHT LOCK LIGHT ANT4X 1LM Remote Antenna Mounting Kit Kit contains antenna bracket and 4 0 m of cable Recommended for increasing the effective range of remote c...

Страница 46: ...ted Warranty we may subject to your other rights and remedies as a consumer charge you a fee to repair replace and or return the Unit to you This Chamberlain Limited Warranty does not cover any failur...

Страница 47: ...45...

Страница 48: ...2012 The Chamberlain Group Inc 01 36600 B All Rights Reserved 18 17 16 15 14 13 12 11 10 TEMPLATE FOR POST BRACKET MOUNTING 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19...

Отзывы: