Specifications

Flow

60 CFM Max. at 90 PSI

Gauge Range

0 PSI ‑ 160 PSI

Max. Pressure

250 PSI

Filtration

5 Microns

Inlet and Outlet Size

3/8″ NPT

Installation

WARNING!  TO PREVENT SERIOUS INJURY:

 

Make sure air supply is off and release all residual 

pressure in system before installing Regulator.

1.  Thread gauge onto front of Regulator body.

2.  Securely mount tool in vertical position as 

close as possible to the tool connection.

Note:

 Air flow must be in the same 

direction as arrow on tool body.

3.  System piping should be 3/8″ minimum. 

Avoid using unnecessary fittings and 

couplings that restrict the flow of air.

4.  Make sure Connector is properly 

installed between the Filter/

Regulator and the Lubricator.

5.  Connect air supply to Inlet Port. 

Connect air tool to Outlet Port.

Inlet

Outlet

Connector

Operating Instructions

1.  Pull Adjustment Knob upwards to 

unlock. Turn Knob counter‑clockwise 

until it stops (closed position).

2.  Turn Adjustment Knob clockwise until 

the desired outlet pressure is reached.

3.  Push down on Adjustment Knob to lock.

Maintenance

BEFORE EACH USE,

 inspect the general 

condition of the tool.  Check for:

•  loose fittings
•  cracked or deformed o‑rings
•  damaged pressure gauge or hose
•  any other condition that may 

affect its safe operation.

1.  Twist and pull downwards to remove Bowl. 

Clean or replace Filter as necessary.

2.  Reinstall Filter and Bowl. Twist 

Bowl to lock in place.