For technical questions, please call 1-888-866-5797.
Item 58184
22g
SAVE THESE INSTRUCTIONS
Record Serial Number Here:
Note:
If product has no serial number, record month and year of purchase instead.
Note:
Reference UPC 193175433947.
Specifications
Flow
60 CFM Max. at 90 PSI
Gauge Range
0 PSI ‑ 160 PSI
Max. Pressure
250 PSI
Filtration
5 Microns
Inlet and Outlet Size
3/8″ NPT
Installation
WARNING! TO PREVENT SERIOUS INJURY:
Make sure air supply is off and release all residual
pressure in system before installing Regulator.
1. Thread gauge onto front of Regulator body.
2. Securely mount tool in vertical position as
close as possible to the tool connection.
Note:
Air flow must be in the same
direction as arrow on tool body.
3. System piping should be 3/8″ minimum.
Avoid using unnecessary fittings and
couplings that restrict the flow of air.
4. Make sure Connector is properly
installed between the Filter/
Regulator and the Lubricator.
5. Connect air supply to Inlet Port.
Connect air tool to Outlet Port.
Inlet
Outlet
Connector
Operating Instructions
1. Pull Adjustment Knob upwards to
unlock. Turn Knob counter‑clockwise
until it stops (closed position).
2. Turn Adjustment Knob clockwise until
the desired outlet pressure is reached.
3. Push down on Adjustment Knob to lock.
Maintenance
BEFORE EACH USE,
inspect the general
condition of the tool. Check for:
• loose fittings
• cracked or deformed o‑rings
• damaged pressure gauge or hose
• any other condition that may
affect its safe operation.
1. Twist and pull downwards to remove Bowl.
Clean or replace Filter as necessary.
2. Reinstall Filter and Bowl. Twist
Bowl to lock in place.