2.2.1 Clearances
Allow adequate clearance for all connections on the rear panel.
Make sure that the clearances provided for the antenna cable respect the
specified minimum bending radius. Minimum bending radius depends on the
cable used, see section
(page
) for applicable values.
If the minimum bending radius of the antenna cable is not respected its impedance
ATTENTION
→
might be altered, compromising the units performance.
2.2.2 Environment
Make sure that temperatures inside the cabinet do not exceed the limits stated
ATTENTION
→
in section
(page
). Appropriate heating or cooling measures must be
provided to guarantee that this requirement is met at all times.
Also, air humidity should respect the limits described in section
(page
2.3 Power Connections
There are two power supply models available for the tīma master clocks. Please
refer to your unit’s SKU and to the information in appendix
(page
) to de-
termine which power supply is installed. See section
on page
to locate
your unit’s SKU.
Alternatively, use the information provided on the label located on the top
cover of the equipment, see figure
Make sure that the voltage provided by the power source is within the limits
specified in section
(page
).
Do not proceed with the installation until you are sure that the correct power
CAUTION
→
source is being used.
• • •
80-300 Vdc
85-264 Vac 50/60Hz
max 10 VA
N/-
POWER SUPPLY
F/+
18-72 Vdc
max 10 VA
• • •
+
-
POWER SUPPLY
1007
4
Figure 2.2: Examples of power supply information on equipment’s top cover
All power connections should use 1.5 mm
2
(16 AWG) cross section insulated
flameproof flexible cables and use the header connector supplied with the
equipment. To reduce the risk of electrical shock, pre-insulated pin terminals
should be used on the ends of the power connections.
6
tīma 2P/2R GPS Master Clocks Reference Manual
Содержание tima 2P
Страница 1: ...tīma 2P 2R GPS Master Clocks Reference Manual tima reference en v3 14 20099 ...
Страница 8: ...4 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 14: ...10 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 20: ...16 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 32: ...28 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 34: ...30 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 40: ...36 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 50: ...46 tīma 2P 2R GPS Master Clocks Reference Manual ...
Страница 55: ......
Страница 56: ...mergedK GmbH Reuchlinstr 10 11 10553 Berlin Germany Tel 49 30 38305710 www mergedk com ...