SETTINGS
40
eng
6. Press the "–" or "+" button to change the tank setting.
MODE
35880
[DOWN] [SAVE]
Tanks
Tank 1 Type
[ UP ]
Tank 1 Vol
Tank 1 Cal
Tank 2 Type
Tank 2 Vol
0.0 G
Not inst.
Fuel
7. Press the "MODE" button to exit the "Tank 1 Type" option.
8. Press the "–" button to highlight the "Tank 1 Vol" capacity.
9. Press the "MODE" button to edit the capacity.
NOTE: The maximum capacity is 2271 liter (600 US gal).
10.Press the "–" or "+" button to change the capacity of the
tank. Holding the button down will scroll through the
numbers.
11.Press the "MODE" button to exit the "Tank 1 Vol" option.
12.Press the "–" button to highlight the "Tank 1 Cal" option.
13.Press the "MODE" button to select the type of calibration.
NOTE: Two different methods are available to calibrate the
tanks: For linear shaped fuel tanks, choose "Default
Calibration." "Default Calibration" assumes the tank is uniformly
shaped and that each quarter of the tank holds a quarter of its
total capacity. Water and waste tanks are typical to this linear
shape tank. For irregularly shaped fuel tanks, choose "Add Fuel
Method." Fuel must be added to the tank for each quarter of the
capacity when using this method. The "Add Fuel Method"
should be performed with the vessel in the water for an accurate
representation of the tank capacity.
NOTE: The following procedure is used for the "Default
Calibration" method.