To drain the recovery tank
Move the machine to your drain area. Use a space with
good water drainage.
Avoid dumping scrub water into areas where water can
collect and bacteria or insects can collect
Remember, this scrub water contains both spent
detergents and soils from the floor. Wear gloves and safety
glasses when draining the tank.
Disconnect the drain hose from th e back of the machine.
Open the plug and lay the hose in the ground
to drain.
When the tanks is drained, reinstall the plug and lock the
hose back into place.
Never drive the autoscrubber with the hose unlocked from
the chassis.
!
!
!
!
!
!
!
Clean the Recovery Tanks
!
!
!
!
!
!
You will empty the recovery tanks on a regular basis. For
detailed cleaning, remove the flush panel and wash
with hose and water.
Inspect batteries regularly, making sure that the battery
fluid levels are above the plate heights.
Fill AFTER charging
Regular maintenance gives longer battery life.
Be sure to close battery caps before operating this
autoscrubber.
Follow charging procedures for your facility and per the
directions on your battery charger.
Clean, Inspect, and Recharge Batteries