Cooling System
Page 7A-6
90-863758060 AUGUST 2006
Openings in seawater pickup should be approximately 3 mm (1/8 in.) maximum to prevent
larger debris from entering and clogging the cooling system.
IMPORTANT: Use a seawater strainer if the seawater pickup openings exceed
3 mm (1/8 in.).
Provisions should be made to minimize galvanic corrosion, given the hull material being
used and the composition of the surrounding components. Some industry standards and
regulations also require that the pickup be connected into the boat's bonding system to
minimize stray current corrosion. Refer to applicable standards and regulations for more
details.
IMPORTANT: External seawater pickup must have an integral seacock.
7532
Typical seacock
7558
h
a
b
c
d
e
f
g
i
j
Typical transom pickup
a -
Hose fitting
b -
Nut (4)
c -
Gasket
d -
O-ring (4)
e -
Washer (4)
f -
Screw (4)
g -
Plastic plug
h -
Pickup
i -
Screen
j -
Screw (2)
Содержание 8.1S Horizon
Страница 5: ...Page iv...
Страница 19: ...Important Information Notes Page 1A 14 90 863758060 AUGUST 2006...
Страница 53: ...Transmission and Drive Line Notes Page 2A 14 90 863758060 AUGUST 2006...
Страница 59: ...Air Intake System Notes Page 4A 6 90 863758060 AUGUST 2006...
Страница 69: ...Fuel Delivery System Page 5A 10 90 863758060 AUGUST 2006 a 14340 Fuel cooler a Gen II fuel cooler...
Страница 119: ...Cooling System Notes Page 7A 22 90 863758060 AUGUST 2006...
Страница 133: ...Electrical System Notes Page 8A 14 90 863758060 AUGUST 2006...
Страница 153: ...Instrumentation and Controls Notes Page 9A 20 90 863758060 AUGUST 2006...
Страница 163: ...Predelivery Preparation Notes Page 10A 10 90 863758060 AUGUST 2006...