background image

 

 User Manual

 

FRONT PANEL: 

-

 

ON/OFF SWITCH – rocker switch to switch unit on and off 

-

 

POWER INDICATOR – solid green LED indicates unit has been switched on 

-

 

FAULT INDICATOR – solid on or flashing red LED indicates fault has occurred,  
refer to fault code for interpretation 

-

 

USB POWER SOCKET – 5V 1.0A USB power supply socket for charging smart phone camera etc 

-

 

UK AC MAINS SOCKET – output UK mains socket provide 230Vac 50Hz mains power 

-

 

GROUND CONNECTION – star washer and nut for ground connection to the outer case (normally 
connected to the vehicle chassis) 
 

BACK PANEL: 

-

 

INPUT BATTERY NEGATIVE CONNECTION – battery input connection to connect negative output 
of the DC power source 

-

 

INPUT BATTERY POSITIVE CONNECTION – battery input connection to connect positive output of 
the DC power source 

-

 

FUSES – location of the fuses  

-

 

FAN DUCT –fan for cooling  - do not obstruct 

 
Temperature and load controlled multi-speed cooling fan: 
The cooling fan is designed to run at a speed in proportion to the load, this minimises the running noise 
and extend fan life. 

-

 

At load lower than 40% or inner temperature less than 30°C the fan will not operate 

-

 

At load between 40% - 60% the fan will operate at 40% of its maximum speed 

-

 

At load between 60% - 80% the fan will operate at 60% of its maximum speed 

-

 

At load between 80% - 100% the fan will operate at 80% of its maximum speed 

-

 

At 100% load or inner temperature exceeds 45°C the fan will operate at 100% of its maximum 
speed 

 

INSTALLATION: 

Location – it is important to for the location of the inverter to meet below requirements: 

-

 

Dry environment where there should be no risk of the inverter coming into contact with water 

-

 

A cool shaded environment where temperature should be 0°C – 40°C,  
not to be placed near any heat source and avoid direct sunlight 

-

 

A well-ventilated area, minimum clearance of two inches should be allowed in front of the 
ventilation duct and fan. Please ensure free flow of air around the unit, if the unit is used to its full 
load, an external fan may be used to aid the cooling of the unit 

-

 

Not to be place in the same compartment as the battery or together with flammable substances 

-

 

Avoid dusty environments, dust can cause blockage of airflow within the inverter  
and cause the unit to overheat 

-

 

Avoid using long input cable run as input voltage can be affected by cable resistance and heat 

Содержание 652.000UK

Страница 1: ...IMS600 24 652 006UK IMS1000 12 652 007UK IMS1000 24 652 008UK IMS1500 12 652 009UK IMS1500 24 652 010UK IMS2500 12 652 011UK IMS2500 24 CAUTION Each model is design to work up to its maximum rated pow...

Страница 2: ...s Unlike pure sine wave inverters modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment For inductive load such as fluorescent light acoustic equipment a...

Страница 3: ...inner temperature less than 30 C the fan will not operate At load between 40 60 the fan will operate at 40 of its maximum speed At load between 60 80 the fan will operate at 60 of its maximum speed A...

Страница 4: ...cessories other than the ones provided may cause damage Mercury will not take any responsible for damage caused by use of third party accessories For cable cross section requirement for different mode...

Страница 5: ...the start up load is normally twice as much as the rated continuous power of the appliance In some equipment the start up load can be as high as 8 times of its continuous power especially on inductiv...

Страница 6: ...onstantly Do not pull on cable when unplugging from the inverter always grip firmly on the plug To avoid shock hazard always ensure inverter and DC power supply if apply are switched off before insert...

Страница 7: ...ash Low input power protection warning the input power is below 10 8V 0 2V for 12V input inverter and 21 6V 0 4V for 24V input inverter This indicates the power bank is running low or DC power supply...

Страница 8: ...on 24V input inverter 1 Check battery level if it is low please recharge before continuing use 2 On the battery cables used check the cross section area of the conductor is no thinner than recommended...

Страница 9: ...ths must be shown for warranty to be valid Any unit that has been misused altered or accidentally damaged will not be covered by warranty Mercury will not be responsible for any damage cause as result...

Страница 10: ...2500W SURGE POWER 200 of Continuous Power for 2 sec to help starting up AC VOLTAGE 230Vac 10 50Hz SIGNAL WAVE FORM Modified Sine Wave USB 5Vdc 1 0A PROTECTIONS 2 Phases Low Battery Protection warning...

Страница 11: ...1 pair 4mm2 20A 4 50Ah IMS1000 12 12V 1 pair 10mm2 35A 4 160Ah IMS1000 24 24V 1 pair 6mm2 20A 4 80Ah IMS1500 12 12V 2 pairs 10mm2 35A 6 250Ah IMS1500 24 24V 2 pairs 6mm2 20A 6 125Ah IMS2500 12 12V 2...

Отзывы: