Below table show recommended accessories specification for each model of inverter: 

MODEL 

INPUT VOLTAGE 

DC INPUT CABLE 

FUSE 

BATTERY 

CAPACITY 

IMS150-12 

12V 

1 pair 2.5mm

2

 

35A 

≥25Ah 

IMS150-24 

24V 

1 pair 2.5mm

2

 

20A 

≥15Ah 

IMS300-12 

12V 

1 pair 4mm

35A 

≥50Ah 

IMS300-24 

24V 

1 pair 2.5mm

20A 

≥25Ah 

IMS600-12 

12V 

1 pair 6mm

2

 

35A*4 

≥100Ah 

IMS600-24 

24V 

1 pair 4mm

2

 

20A*4 

≥50Ah 

IMS1000-12 

12V 

1 pair 10mm

2

 

35A*4 

≥160Ah 

IMS1000-24 

24V 

1 pair 6mm

2

 

20A*4 

≥80Ah 

IMS1500-12 

12V 

2 pairs 10mm

2

 

35A*6 

≥250Ah

 

IMS1500-24 

24V 

2 pairs 6mm

2

 

20A*6 

≥125Ah

 

IMS2500-12 

12V 

2 pairs 16mm

2

 

35A*8 

≥320Ah

 

IMS2500-24 

24V 

2 pairs 10mm

2

 

20A*8 

≥160Ah

 

 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 

This product is classed as Electrical or Electronic equipment and should not be disposed with other 

household or commercial waste at the end of its useful life. The goods must be disposed of according 
to your local council guidelines. 

 

 
 

 

Errors and omissions excepted. 

 

Copyright©  2013. AVSL Group Ltd.

 

Содержание 652.000UK

Страница 1: ...IMS600 24 652 006UK IMS1000 12 652 007UK IMS1000 24 652 008UK IMS1500 12 652 009UK IMS1500 24 652 010UK IMS2500 12 652 011UK IMS2500 24 CAUTION Each model is design to work up to its maximum rated pow...

Страница 2: ...s Unlike pure sine wave inverters modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment For inductive load such as fluorescent light acoustic equipment a...

Страница 3: ...inner temperature less than 30 C the fan will not operate At load between 40 60 the fan will operate at 40 of its maximum speed At load between 60 80 the fan will operate at 60 of its maximum speed A...

Страница 4: ...cessories other than the ones provided may cause damage Mercury will not take any responsible for damage caused by use of third party accessories For cable cross section requirement for different mode...

Страница 5: ...the start up load is normally twice as much as the rated continuous power of the appliance In some equipment the start up load can be as high as 8 times of its continuous power especially on inductiv...

Страница 6: ...onstantly Do not pull on cable when unplugging from the inverter always grip firmly on the plug To avoid shock hazard always ensure inverter and DC power supply if apply are switched off before insert...

Страница 7: ...ash Low input power protection warning the input power is below 10 8V 0 2V for 12V input inverter and 21 6V 0 4V for 24V input inverter This indicates the power bank is running low or DC power supply...

Страница 8: ...on 24V input inverter 1 Check battery level if it is low please recharge before continuing use 2 On the battery cables used check the cross section area of the conductor is no thinner than recommended...

Страница 9: ...ths must be shown for warranty to be valid Any unit that has been misused altered or accidentally damaged will not be covered by warranty Mercury will not be responsible for any damage cause as result...

Страница 10: ...2500W SURGE POWER 200 of Continuous Power for 2 sec to help starting up AC VOLTAGE 230Vac 10 50Hz SIGNAL WAVE FORM Modified Sine Wave USB 5Vdc 1 0A PROTECTIONS 2 Phases Low Battery Protection warning...

Страница 11: ...1 pair 4mm2 20A 4 50Ah IMS1000 12 12V 1 pair 10mm2 35A 4 160Ah IMS1000 24 24V 1 pair 6mm2 20A 4 80Ah IMS1500 12 12V 2 pairs 10mm2 35A 6 250Ah IMS1500 24 24V 2 pairs 6mm2 20A 6 125Ah IMS2500 12 12V 2...

Отзывы: