600.101/102UK User Manual

 

 

Warning 

 

To avoid possible electric shock or personal injury, and to 
avoid possible damage to the Meter or to the equipment 

under test, adhere to the following rules:

 

 

Before using the Meter inspect the case. Do not 
use the Meter if it is damaged or the case (or part 
of the case) is removed. Look for cracks or missing 
plastic. Pay attention to the insulation around the 

connectors. 

 

Inspect the test leads for damaged insulation or 
exposed metal. Check the test leads for continuity. 

 

Do not apply more than the rated voltage, as 
marked on the meter, between the terminals or 
between any terminal and grounding. 

 

The rotary switch should be placed in the right 

position and no changeover of range shall be 

made during measurement being conducted to 
prevent damage of the Meter. 

 

When the meter working at an effective voltage 
over 60V in DC or 30Vrms in AC, special care 

should be taken for there is danger of electric 

shock. 

 

Use the proper terminals, function, and range for 

your measurements. 

 

Do not use or store the meter in an environment of 

high temperature, humidity, explosive, 
inflammable, and strong magnetic field. The 
performance of the meter may deteriorate after 

dampened. 

 

When using the test leads, keep your fingers 

Содержание 600.101UK

Страница 1: ...Please read this manual thoroughly and ensure all contents are fully understood before use of the apparatus WARNING MTB01 MTB02 Digital Multimeter Item Ref 600 101UK 600 102UK...

Страница 2: ...re than the rated voltage as marked on the meter between the terminals or between any terminal and grounding The rotary switch should be placed in the right position and no changeover of range shall b...

Страница 3: ...ning the meter case The internal circuit of the meter shall not be altered at will to avoid damage of the meter and any accident Soft cloth and mild detergent should be used to clean the surface of th...

Страница 4: ...Measure method double integral A D switch implement Sampling speed 2 times per second Over load indication 1 is displayed Operating Environment 0 40 at 80 RH Storage Environment 10 50 at 85 RH Power 9...

Страница 5: ...600 101 102UK User Manual COM jack V mA jack 10A jack hFE socket LCD RANGE switch...

Страница 6: ...ION ACCURACY 200mV 100uV 0 5 of rdg 3D 2000mV 1mV 20V 10mV 200V 100mV 500V 1V 1 0 of rdg 5D 0 8 of rdg 5D OVERLOAD PROTECTION 220V rms AC for 200mV range and 500V DC or 500Vrms for all ranges AC VOLTA...

Страница 7: ...E RESOLUTION ACCURACY 200uA 100nA 2000uA 1uA 20mA 10uA 200mA 100uA 2 0 of rdg 2D 5A 10mA 2 0 of rdg 10D 1 8 of rdg 2D OVERLOAD PROTECTION F0 5A 250V and F5A 250V fuse MEASURING VOLTAGE DROP 200mV RESI...

Страница 8: ...splay along with the voltage polarity DC CURRENT MEASUREMENT 1 Red lead to V mA Black lead to COM for measurements between 200mA and 5A connect red lead to 5A jack with fully depressed 2 Set RANGE swi...

Страница 9: ...he forward voltage drop in mV will be displayed If the diode is reversed figure 1 will be shown TRANSISTOR hFE MEASUREMENT 1 Set RANGE switch to the hFE position 2 Determine whether the transistor is...

Страница 10: ...he old and replace with a new one Be careful to observe polarity ACCESSORIES Operator s instruction manual Set of test leads red and black 9 volt battery NEDA 1604 6F22 type EN61010 1 2010 This produc...

Отзывы: