RESISTANCE
RANGE RESOLUTION
ACCURACY
200
Ω
100m
Ω
± 1.0% of rdg ± 2D
2000
Ω
1
Ω
20K
Ω
10
Ω
200K
Ω
100
Ω
± 0.8% of rdg ± 2D
2000K
Ω
1K
Ω
± 1.0% of rdg ± 2D
Maximum open circuit voltage: 3.2V.
Overload Protection: 15 seconds, maximum 220Vrms.
AUDIBLE CONTINUITY
RANGE DESCRIPTION
The built-in buzzer will sound if resistance of
the circuit under test is less then 50
Ω
.
TEMPERATURE (K TYPE PROBE)
RANGE RESOLUTION
ACCURACY
0~1000ºC
1ºC
± 2.0% of rdg ± 3D
OPERATING INSTRUCTION
DC VOLTAGE MEASUREMENT
1.
Connect the red test lead to the "V
Ω
mA" jack and the black
test lead to the "COM" jack.
2.
Set the Function / Range switch to the desired DCV
position. If the voltage to be measured is not known
beforehand, set the range switch to the highest range and
then turn it down until satisfactory reading is obtained.
3.
Connect the test leads to the device or circuit to be
measured.
4.
Turn on the power of the device to be measured. The
voltage value will appear on the LCD along with the voltage
polarity.
Содержание 600.032