![Mercury 300XS OptiMax Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/mercury/300xs-optimax/300xs-optimax_manual_1773518051.webp)
FUEL AND OIL
eng
45
2. Open the manual vent screw on top of the cap for operation and cap
removal. Close the manual vent screw for transportation.
3. For fuel hoses that have quick disconnects, disconnect the fuel line from
the engine or fuel tank when not in use.
4. Follow
Filling Fuel Tank
instructions for fueling.
Filling Remote Oil Tank
Remove the filler cap and fill with the specified oil. Oil tank capacity is
11.5 liters (3 gallons). Replace the filler cap and tighten securely.
IMPORTANT: Always make sure the oil tank caps are threaded on tight. An air
leak will prevent oil flow to the engine.
2723
Filling Engine Mounted Oil Reservoir Tank
NOTE: Filling this tank is only necessary if the oil level should ever drop and
the low oil warning system is activated.
1. Remove the top cowl.
2. Loosen the fill cap on the engine oil reservoir tank. Run the engine until all
the air has been vented out of the oil reservoir tank and tank is filled with
oil to the point of overflow.
3. Tighten the fill cap. Stop the engine and replace the top cowl.
29424