3. Turn the ignition key "ON." The fuel pumps will run for approximately five
seconds.
4. Turn the ignition key to the "START" position and release the key. The
ECM controls the activation of the starter. The starter may continue
cranking for up to eight seconds.
NOTE: When priming a drained fuel system, residual fuel may cause the
engine to flare and stall which shortens the engine cranking event.
5. Continue with the ignition key "ON" and "START" sequence until the
engine continues to run.
IMPORTANT: Allow the starter motor to cool for 20 to 30 seconds between full
eight second crank events. Limit the number of events to a maximum of 10 full
eight second cranking events.
6. Once the engine starts, it may run rough at idle for up to two minutes
while the residual air is purged from the fuel system.
7. If the fuel system will not prime within 10 full eight second cranking
events, use the previous procedure
Priming the FSM with a Purge Tool
to prime the fuel system.
Starting the Engine
Before starting, read the
Prestarting Check List
, special operating
instructions,
Engine Break
‑
in Procedure
,
Gear Shifting
, and the remote
control features and operation in the
Features and Controls
section.
NOTICE
Without sufficient cooling water, the engine, the water pump, and other
components will overheat and suffer damage. Provide a sufficient supply of
water to the water inlets during operation.
1. Verify the cooling water intake is submerged.
28928
OPERATION
78
eng
Содержание 225 OptiMax
Страница 2: ...eng ...
Страница 136: ...Quantity Item Stock Number Price Total Total Due OWNER SERVICE ASSISTANCE 126 eng ...