![Mercury Floor Machines 1.5 HP 1170 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/mercury-floor-machines/1-5-hp-1170/1-5-hp-1170_safety-operation-and-maintenance-manual-with-parts-list_1773680003.webp)
1.1 Electrical Power
This burnisher operates on a 13 amp nominal 115 V,
60 Hz, A.C. power circuit. (Motors may be custom
wired at the factory for 220 V, 50 Hz international
operation). The amp, hertz and voltage ratings are
listed on the motor spec label found on each burnisher.
Using voltages above or below those indicated on the
spec label will damage the motor. Always check your
local voltage requirements.
1.2 Grounding Instructions
This burnisher must be grounded while in use to
protect the operator from electrical shock. This
machine is built with a 3-wire cord and a 3-prong
grounding-type plug (Figure 1) to fit a properly
grounded receptacle.
Before using this burnisher, make sure a properly
grounded, 3-hole electrical outlet is available. If not
available, as in some older facilities, use an adapter
for connecting a 3-prong plug to a 2-prong receptacle
(Figure 2) to ground the outlet chassis.
IMPORTANT: This adaptor may not be used in
Canada.
IMPORTANT: Never cut off the grounding prong for
use in a 2-prong outlet. By doing so, you have cut off
your protection from electrical shock.
Never assume that all 3-hole outlets are properly
grounded. Check before use.
Never assume that an adaptor connection (as in
Figure 2) is properly grounded. Check the outlet
with a ground fault interrupter device which quickly
indicated if a ground is connected. Correct a faulty
grounding before proceeding.
1.3 Extension Cords are Not Recommended
The burnisher is built with a 50 foot (15 M) safety cord which plugs directly into an
approved outlet. Use of any extension cords is NEVER RECOMMENDED.
(10) Ultra High-Speed Burnisher
Ultra High-Speed Burnisher (3)
7.0 Machine Schematic Drawing
Figure 1
Figure 2