Mercury Floor Machines 1.5 HP 1170 Скачать руководство пользователя страница 3

1.1   Electrical Power

This burnisher operates on a 13 amp nominal 115 V, 

60 Hz, A.C. power circuit. (Motors may be custom 

wired at the factory for 220 V, 50 Hz international 

operation). The amp, hertz and voltage ratings are 

listed on the motor spec label found on each burnisher. 

Using voltages above or below those indicated on the 

spec label will damage the motor. Always check your 

local voltage requirements.

1.2   Grounding Instructions

This burnisher must be grounded while in use to 

protect the operator from electrical shock. This 

machine is built with a 3-wire cord and a 3-prong 

grounding-type plug (Figure 1) to fit a properly 

grounded receptacle.
Before using this burnisher, make sure a properly 

grounded, 3-hole electrical outlet is available. If not 

available, as in some older facilities, use an adapter 

for connecting a 3-prong plug to a 2-prong receptacle 

(Figure 2) to ground the outlet chassis.
IMPORTANT: This adaptor may not be used in 

Canada.
IMPORTANT: Never cut off the grounding prong for 

use in a 2-prong outlet. By doing so, you have cut off 

your protection from electrical shock.
Never assume that all 3-hole outlets are properly 

grounded. Check before use.
Never assume that an adaptor connection (as in 

Figure 2) is properly grounded. Check the outlet 

with a ground fault interrupter device which quickly 

indicated if a ground is connected. Correct a faulty 

grounding before proceeding.

1.3   Extension Cords are Not Recommended

The burnisher is built with a 50 foot (15 M) safety cord which plugs directly into an 

approved outlet. Use of any extension cords is NEVER RECOMMENDED.

(10) Ultra High-Speed Burnisher

Ultra High-Speed Burnisher (3)

7.0   Machine Schematic Drawing

Figure 1

Figure 2

Отзывы: