– disabled (pass protected)
1
– enabled (no pass protect.)
A_14
[ 0 ]
L1 limit display
in main display mode
With options 1 and 2, settings the L1 limit value is not
password-protected, option 2 allows you to change the L1 limit
within preseted range (at A_60 and A_61)
2
– enabled within preseted
range (A_60 & A_61)
A_15
[ 20.00 ]
Limit L1
value
+/- 60000 digits
A_16
[ 0.01 ]
Limit L1
numeral hysteresis
value
0 to 30000 digits
A_17
[ 0,5 ]
Limit L1
time hysteresis
value
0 to 299,9 seconds
0
– level mode inverse
1
– level mode direct
2
– window mode inverse
A_18
[ 0 ]
Limit L1
control settings
3
– window mode direct
0
– disabled (pass protected)
A_19
[ 0 ]
L2 limit display
in main display mode
With options 1 settings the L1 limit value is not pass-protected
1
– enabled (no pass protect.)
A_20
[ 40.00 ]
Limit L2
value
+/- 60000 digits
A_21
[ 0.01 ]
Limit L2
numeral hysteresis
value
0 to 30000 digits
A_22
[ 0.5 ]
Limit L2
time hysteresis
value
0 to 299,9 seconds
0
– level mode inverse
1
– level mode direct
2
– window mode inverse
A_23
Limit L2
control settings
3
– window mode direct
0
– 0 to 20 mA
1
– 4 to 20 mA
2
– 0 to 10 V
3
– user output 0 to 20 mA
4
– user output 4 to 20 mA
A_24
[ 1 ]
Output signal
type setting
Option 3, 4 and 5 allows you to assign a user-defined scale
range (A_25 and A_26) to the selected analog output type
5
– user output 0 to 10 V
A_25
[ 0.00 ]
User output signal scale start point
+/- 60000 digits
A_26
[ 200.00 ]
User output scale signal end point
+/- 60000 digits
0
– disabled (pass protected)
A_44
[ 0 ]
L3 limit display
in main display mode
With options 1 settings the L1 limit value is not pass-protected
1
– enabled (no pass protect.)
A_45
[ 60.00 ]
Limit L1
value
+/- 60000 digits