1. INTRODUCTION____________________________________________________  

The  aim  of  this  Technical  and  Operational  Documentation  is  to  acquaint  the  user  with  the  purpose, 
construction, principle of operation, correct installation and operation of the product. 
The  Documentation  contains  also  additional  information  on  operating  conditions,  maintenance,  and 
terms of guarantee of the product. 
The Documentation concerns the entire group of overpressure dampers of mcr PL1 type. Observing the 
recommendations  contained  in  this  Documentation  shall  ensure  correct  functioning  of  the  device  as 
regards fire protections of rooms, as well as safety of the system users. 
 
 

2. SUBJECT MATTER OF THE DOCUMENTATION ___________________  

The subject matter of the present Technical and Operational Documentation are: 

  Rectangular overpressure-bleed dampers mcr PL1 

 
 

3. PURPOSE OF THE DEVICE_________________________________________  

 

Application ________________________________________________________________________  

Dampers  of  mcr  PL1  type  are  used  as  bleed  dampers  in  overpressure  systems  of  staircases.  These 
devices  can  also  be  applied  in  any  premises  that  are  protected  against  smoke  with  overpressure.  The 
function of the dampers is to maintain an adequate differential pressure before and behind their partition, 
thus operating as so-called safety valves that prevent the increase of pressure above a set value, e.g. in 
a protected staircase. The devices meet the requirements of the PN-EN 12101-6 standard. 
 

Fire Resistance ___________________________________________________________________  

The device does not feature fire resistance, as it is not required for its correct operation. 
 

Execution Versions _______________________________________________________________  

  Wall-mounted - S 

  Duct-mounted - K 

 
 

4. CONSTRUCTION AND PRINCIPLE OF OPERATION________________  
    

Construction ______________________________________________________________________  

The  mcr  PL1  damper  consists  of  a  casing  made  of galvanised  steel  sheet,  1.25 mm thick  (1),  with  an 
embedded baffle made of rotating blades (2). Individual blades of the baffle are made of galvanised steel 
sheet of a specially designed shape. Owing to their multi-layer design, the rotating blades do not move 
outside the casing of the damper. Individual blades of the baffle feature weights that impose load on the 
baffle  (4). The  weights  are  made  of  steel  straps of  a  suitable  mass  and shape  that  provide  the  device 
with  a  required  working  point  and  the  speed  of  action  and  reaction  to  changing  pressures.  Along  the 
width  of  the  damper,  polyethylene  straps  gaskets  are  glued  in  order  to  provide  better  tightness  of  the 
device (3). 
In order to limit an opening angle of blades, steel opening and closing limiters are mounted on the casing 
of the damper. The design and manufacturing of the device provide the fast reaction that complies with 
the PN-EN 12101-6 standard. 

Содержание mcr PL1

Страница 1: ... 08 GDAŃSK 2008 ul Grzegorza z Sanoka 2 80 408 Gdańsk tel 48 58 341 42 45 tel fax 0 58 341 39 85 TECHNICAL AND OPERATIONAL DOCUMENTATION Overpressure bleed damper of mcr PL1 type FIRE VENTILATION SYSTEMS DEPARTMENT ...

Страница 2: ... THE DOCUMENTATION 3 3 PURPOSE OF THE DEVICE 3 4 CONSTRUCTION AND PRINCIPLE OF OPERATION OF THE DEVICE 3 5 DESIGNATION OF THE DEVICE 6 6 INSTALLATION OF THE DEVICE 6 6 1 PRE INSTALLATION INSPECTION 6 6 2 INSTALLATION OPENING 6 6 3 EMBEDDING 7 6 4 ELECTRICAL CONNECTIONS 8 7 TRANSPORT AND STORAGE CONDITIONS 8 8 MAINTENANCE AND SERVICE 8 9 TERMS OF GUARANTEE 9 ...

Страница 3: ...r partition thus operating as so called safety valves that prevent the increase of pressure above a set value e g in a protected staircase The devices meet the requirements of the PN EN 12101 6 standard Fire Resistance ___________________________________________________________________ The device does not feature fire resistance as it is not required for its correct operation Execution Versions __...

Страница 4: ...uitable flow of an air stream Driving and Tripping Systems ____________________________________________________ The driving system of mcr PL1 dampers is made of suitably selected steel weights that are mounted on blades of the device Dimensions _______________________________________________________________________ Mcr PL1 dampers are manufactured in the following dimensions Height Breadth B mm H ...

Страница 5: ...ssembly sets are made of a suitable number of single dampers of the basic type as well as flat bars and connecting elements Basic dimensions of mcr PL1 dampers have been presented on the drawing below 3 2 4 1 Technical characteristics 50 55 60 65 70 75 80 85 90 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 discharge V m3 h pressure P Pa PL500x500 PL600x600 PL750x750 PL400x400 NOTE Net dime...

Страница 6: ...TION INSPECTION __________________________________________ Each damper is inspected before packing and shipment by the manufacturer After unpacking at the recipient perform visual inspection to check if the casing has not been deformed and whether the damper has not been damaged during transport 6 2 INSTALLATION OPENING _________________________________________________ The minimum size of the open...

Страница 7: ...mper with protective film or other covering material before installation until the masonry and finishing work is completed After the concrete mortar sets remove the brackets and open individual blades of the damper manually to check if they operate correctly Connection of the embedded damper to the ventilation duct must be executed coaxially During installation of the damper in the partition a dam...

Страница 8: ...r each transport each damper should be visually inspected The damper must not be hit or dropped During handling and installation attention should be paid to the damper baffle The dampers should be stacked in no more than 2 layers vertically in closed rooms ensuring protection against external weather conditions In the case of storing of the dampers on the ground they should be placed on protective...

Страница 9: ...ull value with no financial consequences to the purchaser 5 The guarantee does not include the operations performed by the purchaser user specified in the Documentation 6 The Manufacturer is absolved from the guarantee and any obligations resulting from the guarantee if a the product has mechanical damage created due to improper transport or unloading using own means of the purchaser improper inst...

Отзывы: