P 5
Please retain product label and instructions for future reference
Step 9
Place the assembled roof panels
on to the building and secure as
shown in the illustration with
18x30mm screws
* Ensure the roofs are flush with
the sides of the building. Ensure
the eaves frame sits over the
window and door panels.
18x30mm Screws
Pre drill
hole
30mm
screw
*If you have purchased the T&G roof and floor option ensure to fix
the roof to the building using 18x70mm screws following the
same method outlined above.
Internally
: Secure the roof panels together where they join using
5x50mm screws.
18x70mm Screws
5x50mm Screws
Pre drill
hole
70mm
screw
50mm
screw
Step 10
Secure the building to the
floor using 18x50mm screws.
*Ensure to screw through the framing
into the floor bearers.
18x50mm Screws
Pre drill
hole
50mm
screw
b
b
b
b
b
b
b
b b
b
b
HANDLE
WITH CARE
1
2
3
4
Step 11
Cut the felt into 2 sheets and lay
onto the roof.
* Ensure there is approximately
50mm of overhang around the
building.
Fix into place using 175x felt tacks
at 100mm intervals.
175xFelt Tacks
Felt
tacks
Felt size: 10x6 - 3200mm
12x6 - 3740mm
14x6 - 4370mm
Step 12
Measure the side of the roof,
cut 2x
(No.19)
fascias to size and fix in
place using 3x30mm screws.
Measure the distance between
the 2 facias at the front of the
building & cut 2x
(No. 19)
facias to match
the gap. Secure to the building
using 6x30mm screws.
12x30mm Screws
Cut down to fit
Pre drill
hole
30mm
screw
19
19
19
19