Multitest ND
Operator's manual
-
15
-
Mask
—exhalation-valve opening pressure
Strap the mask onto the dummy head.
Connect the testing hose to the tester and the mask.
Move the “pressure pump” lever to the “OPEN” position.
Press the pump push-button.
Perform the test against the specifications provided by the equipment
manufacturer.
Chemical protective suit
Preparing the suit for testing
Unfold the suit on a workbench or the clean floor.
Remove all valve chambers.
Remove all exhalation-valve disks.
Connect the testing hose to the exhalation valve.
Attach the testing hose to the tester's equipment connector.
Connect the filling hose to the exhalation valve.
Connect the filling valve to the medium-pressure supply.
Seal all other exhalation valves of the suit.
Letting the suit pressure stabilize
Use the filling valve to adjust the pressure to the level that is required for
testing according to the suit manufacturer.
CAUTION: Never increase the pressure in the suit beyond the
required stabilization pressure. Otherwise, seams and joints may
get damaged.
Perform the test against the specifications provided by the equipment
manufacturer.