PA�ALM 08
PANIC 15
FUSE 01
C.TMP 02
DELAY 05
ENTRY 01
FIRE 07
Display Messages (Cont.)
A passcode has been incorrectly entered more than four times at a remote
keypad (keypad 02). To silence the alarm enter a correct passcode. To
reset the alarm simply enter your passcode follows by [ESC].
A delayed full alarm has occurred from a detection circuit (circuit 05). This
message is normally display after unsetting the alarm system. Before the
system can be set again the alarm system must be reset,
see “Resetting
After an Alarm” on page 11.
An entry time out alarm has occurred from a detection circuit (circuit 01).
This is normally caused when the entry procedure is started and the system is
not unset before the timer expires. Before the system can be set again the
alarm system must be reset,
see “Resetting After an Alarm” on page 11.
A fire alarm has occurred from a detection circuit (circuit 07). The internal
sounder will generate a distinctive fire alarm tone and the external sounder
is pulsed on and off. To silence the alarm simply enter your passcode. To
reset the alarm simply enter your passcode again followed by [ESC].
The auxiliary supply used for powering detection devices has blown its fuse.
You will not be able to set the alarm system until the fault is rectified. Contact
your alarm company for further advice.
A panic alarm (PA) has occurred from a detection circuit (circuit 08). To
silence the alarm simply enter your passcode. Reset the panic alarm
device if required (normally with a key). To reset the alarm simply enter your
passcode again followed by [ESC].
A panic alarm (PA) passcode has been entered at a remote keypad by a
user (user 15). To silence the alarm simply enter your passcode. To reset the
alarm simply enter your passcode again followed by [ESC].
CODE TAMPER 02
17:30
01 Jan
C.TMP 02
PT.02
DELAY ALARM 05
17:30
01 Jan
DELAY 05
AD.05
ENTRY ALARM 01
17:30
01 Jan
ENTRY 01
EA.01
FIRE ALARM 07
17:30
01 Jan
FIRE 07
FA.07
FUSE BLOWN 01
17:30 01 Jan
FUSE 01
FB.01
PA ALARM 08
17:30
01 Jan
PA�ALM 08
PA.08
PA CODE 15
17:30
01 Jan
PANIC 15
PC.15
41
Содержание TS690
Страница 45: ...Service Record Date Engineer Action 45...
Страница 47: ...Notes 47...