SUMMARY OF PCS 400 FUNCTIONS
Below is a list giving a brief description of the various functions available to the
PCS 400
. This listing begins
with descriptions of the three function keys on the bottom row, progresses from [1] through [9] in numerical
order, then ends with [CE], [+] and [-]. The listing begins with the key cap inscription shown in brackets,
followed by the mode legend for the key in capital letters, and finally a sentence or so of descriptive text.
Detailed explanations for all of the functions, and how to access them, are provided in Section 3,
Local
Operation
. Additional information can also be found in Section 4,
Remote Operation
.
KEY
FUNCTION
DESCRIPTION
[0]
F1
Function key F1 is used only with certain options.
[.]
F2
Sequences: Macros which can be created, edited, run and deleted.
[=]
F3
Function key F3 is used only with certain options.
[1]
CALIBRATION
Allows the user to calibrate transducers and some functions
of the instrument.
Sensor Zero
Calibrate A/D
Baro Cal
Sensor Span
Calibrate Auxiliary Sensor
Save Control Settings
[2]
TEST
Provides the means to quickly test various internal electrical and
pneumatic functions or components. (Does not apply to HPCU.)
All Tests
Regulator
Display
Solenoid Valves
Sensor
Internal Leak
Keypad
Program Memory
Source Pressure
System Leak
Program
[3]
LIMITS
Allows the operator to select certain items or functions and set
parameters.
Active Transducer
Cont Stable Window & Delay
Restore Defaults
Control Limits
Press/Rate/Peak
Chg Passwords
Filter
Display Resolution
[4]
METRIC
Allows the user to convert pressure reading to the metric units
selected from a list. The selected units will be displayed with any
mode that displays pressure readings.
[5]
ENGLISH
Allows the user to convert pressure readings to selected English units.
[6]
GPIB
Provides a means to set up parameters for use with GPIB communi-
cations.
Address
Termination Character
[7]
STANDBY
Places instrument in the “Standby Mode”. The last measured or
controlled pressure will be displayed.
[8]
MEASURE
Measures the pressure at the “Measure/Control” pressure port.
[9]
CONTROL
Generates a pressure in response to a command point set via the
keypad or a remote command.
PCS 400
INTRODUCTION
www.mensor.com
1-5
Содержание PCS 400
Страница 13: ...User s Notes TABLE OF CONTENTS PCS 400 xii www mensor com ...
Страница 23: ...User s Notes INSTALLATION PCS 400 2 4 www mensor com ...
Страница 41: ...User s Notes LOCAL OPERATION PCS 400 3 18 www mensor com ...
Страница 73: ...User s Notes SPECIFICATIONS PCS 400 7 4 www mensor com ...
Страница 115: ...User s Notes INDEX PCS 400 10 6 www mensor com ...
Страница 116: ......