85-03-01194
FV48
Page
57
4.10
NATURAL GAS TO LPG CONVERSION
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide
may result causing property damage, personal injury or loss of life . The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
A natural gas to LP gas conversion kit #HA-110-00084 must be ordered and installed in this fireplace to burn LP gas.
LP conversion kit #HA-110-00084 contains the following parts: one motorized LP pressure regulator #907.012, two cap orifices
#65-14-00054 (
drill #54),
an L-shaped Torx wrench and an LP conversion label.
Figure 4-9 LP Kit Contents
Procedure to Convert Fireplace for LP Gas
This fireplace arrives from the factory ready to burn natural gas. If you intend to burn LP gas, it is highly recommended that you
convert this fireplace and its pressure regulator, pilot natural gas/LP clip position and burner orifices prior to placing this
fireplace in its fireplace cavity.
Follow the step below to prepare this fireplace for conversion to LP gas:
1.
Using a ¼” hex dri
ver, remove the 3 screws that secure the rear and front burners to the burner airbox.
2.
Lift up and remove the burners.
3.
Using a ¼” hex driver, remove the two screws that secure the airbox to the fireplace floor.
4.
Lift up and remove the airbox.
5.
You will now be able to access the burner
orifices, which are located inside the air
shutter boxes.
Using a ½” deep well
socket wrench, remove front and rear
orifices. When removing and installing
the orifices be sure to use a wrench to
keep the fitting the orifice screws onto
from rotating.
6.
Thread a new #54 orifice on both the
front and rear orifice mounting brass
fittings. Tighten down the orifices.
LP CONVERSION LABEL
(MUST BE FILLED OUT AND
ATTACHED TO FIREPLACE)
MOTORIZED LP REGULATOR
[10.0"-5.5" WC] #907.012
TORX WRENCH
BURNER ORIFICE
#54
Figure 4-10 PREPARATION FOR CONVERSION
BURNER SCREWS
AIR BOX SCREWS
ORIFICE LOCATION
Содержание FV48
Страница 2: ...85 03 01194 C FV48...
Страница 16: ...85 03 01194 FV48 Page 16 Figure 3 11 Figure 3 10...
Страница 89: ...85 03 01194 FV48 Page 89 Gas Train Assembly Parts Figure 6 5 Gas Train Assembly Parts...
Страница 90: ...85 03 01194 FV48 Page 90 Burners Figure 6 6 Burners...
Страница 97: ......
Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...