TEMPERATURE INDICATOR (

o

F or 

o

C) 

1.

 Press the ON/OFF Key and Turn Off the Fireplace. 

2.

 Simultaneously, Press both the MODE Key and the Thermostat 

Key. 

3.

 Look at the LCD display to verify that your desired indicator (

o

F or 

o

C) is being displayed. If not, repeat step 2.

 

 
 

 

KEY LOCK FUNCTION 

To prevent unsupervised children from operating the fireplace, a KEY LOCK function is 
provided with this remote control system. To activate the KEY LOCK function, simultane-
ously press the “MODE KEY” and the “UP KEY”. To deactivate the KEY LOCK function, 
simultaneously press the “MODE KEY” and the “UP KEY”. 
During KEY LOCK mode, none of the Keys will function. You must DEACTIVATE the sys-
tem before you can use the Remote Transmitter. 
 

 

LOW BATTERY POWER DETECTION 

1. 

Transmitter Batteries

:  The life span of the remote control transmitter batteries depends 

on various factors: quality of the batteries used the number of ignitions of the appliance, 
the number of changes to the room thermostat set point, etc.  When the Transmitter bat-
teries are low, a Battery Icon will appear on the LCD display of the Transmitter before all 
battery power is lost. When the batteries are replaced, this icon will disappear. 

2. 

Wall Receiver Batteries

:  The life span of the wall receiver batteries depend on the 

quality of the batteries used and how long the batteries have been installed in the wall receiver. These batteries are 
only utilized during power outages.  Replace these batteries every heating season even if you have not experienced 
any power outages. Batteries drain slowly even when not in use. This is a normal characteristic of all batteries. 

 

OPERATING DURING POWER OUTAGES 

This electronic ignition system utilizes the supplied 110VAC power when it is available for all functions of this system. If 
the AC power is interrupted during a power outage, plug in the battery pack (6V DC Max, supplied with this fireplace) to 
the Fireplace Backup Power Inlet Port installed on the Surround on the left side of the fireplace insert or in the gap to the 
left of the glass frame, directly beneath the Master Switch.  

During the power outage, the appliance’s burners will 
function. In addition, Flame Height adjustment and 
Secondary Burner ON/OFF functions will be availa-
ble. The Fan and Accent Light, which are wholly de-
pendent on 110VAC power, will not function. 

This appliance is designed and tested to be operated 
during power outages. The overall efficiency of this 
appliance will be reduced by approximately 5% when 
the blower function is disabled during the power out-
age period. 
You may operate this appliance indefinitely on bat-
tery power as long as you accept that high capacity 
DC 6 volt batteries will be required to sustain uninter-
rupted DC power to this appliance and that the blow-
er function and accent light functions will not be 
available.

Содержание FV-33i

Страница 1: ... in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FOR YOUR SAFETY A qualified installer service agency or the gas suppli er must perform installation and service Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other ap p...

Страница 2: ...TRUCTIONS 7 TO TURN ON THE APPLIANCE 7 TEMPERATURE INDICATOR O F OR O C 8 KEY LOCK FUNCTION 8 LOW BATTERY POWER DETECTION 8 OPERATING DURING POWER OUTAGES 8 FIRST TIME PILOT LIGHTING INSTRUCTIONS 9 INITIALIZING THE REMOTE CONTROL SYSTEM 9 IPI STANDING PILOT SYSTEM INFORMATION 10 DOOR REMOVAL AND REPLACEMENT 11 BLOWER OPERATION AND WIRING 12 MENDOTA WARRANTY QUALIFICATION SERVICE REFERENCE FORM 13 ...

Страница 3: ... NOT BE PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance These units MUST use one of the vent systems described in the Installing Your Fireplace section of the Installers Guide NO OTHER...

Страница 4: ...C COMBUSTION SYSTEM DUAL HOT AIR BLOWERS PREMIUM 8 PIECE FIBER LOG SET COALS NEO CERAM GLASS THERMOSTATIC REMOTE ELECTRONIC IGNITION AGA CERTIFIED SAFETY SYSTEM NOTE LPG CONVERSION KIT HA 82 00411 MUST BE PURCHASED SEPARATELY TO CONVERT TO BURN LPG IN THIS FIREPLACE INSERT APPLIANCE CERTIFICATION AND TESTING AGENCY INTERTEK TESTING SERVICES ICBO AA647 4 Certified under ANSI Z21 88 2005 CSA 2 33 20...

Страница 5: ...efore use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control com partments burners and circulating air passageways of the appliance be kept clean The burner and pilot flames and logs should be visually checked periodically DO NOT use this appliance if a...

Страница 6: ...s displayed in the SET POINT TEMPERATURE window The fan will turn on 5 minutes after fireplace startup and will turn off 12 1 2 minutes after the flames turn off in this mode The flame height can be adjusted while the fireplace is func tioning fan speed can be adjusted after 5 minutes of startup Secondary burner can be turned On or Off at any time after startup The Accent Light can be turned on or...

Страница 7: ...ot Mode the pilot light will remain ON Note If in SMART model the flame height function is not available for manual adjustment In SMART mode the flame height regu lates automatically Fan Speed Control The fan speed can be adjusted through six 6 speeds and OFF To activate this function press the MODE Key to index to the fan control icon Use the UP Down Arrow Key to turn ON OFF or adjust the fan spe...

Страница 8: ...and how long the batteries have been installed in the wall receiver These batteries are only utilized during power outages Replace these batteries every heating season even if you have not experienced any power outages Batteries drain slowly even when not in use This is a normal characteristic of all batteries OPERATING DURING POWER OUTAGES This electronic ignition system utilizes the supplied 110...

Страница 9: ...quence until the pilot flame lights and the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doing so will lead to damage to pilot flame sensor and spark elec trode wire leads 8 Press the ON OFF button on Transmitter to ON All burners should ignite and run at high fire Toggle through othe...

Страница 10: ...n ON while the main fireplace burners are operating IPI Mode This mode turns the pilot light OFF when the fireplace is not functioning and only lights the pilot light automat ically when a call for heat is made by the remote control CPI Standing Pilot Mode If set to CPI Mode the pilot light will ignite and remain ON at all times Setting to IPI versus CPI mode With the remote transmitter OFF press ...

Страница 11: ...atches exist at top of glass frame 2 Pull Glass Latch Tool outward about 3 8 3 Rotate Glass Latch Tool 90 degrees 4 Release Glass Latch Tool 5 Remove Glass Latch Tool To Latch Glass Frame Latches reverse steps 5 to 1 above To Remove Glass Frame a Rotate top edge of freed glass frame outward about 15 degrees b Lift Glass Frame Up and Out To Install Glass Frame 1 Align and insert tabs in side flange...

Страница 12: ... may take longer to break in and may require addi tional operation time before all extraneous noise is eliminated Please allow adequate operational time for the blowers to break in before you contact your dealer for service BLOWER OPERATION The remote control system supplied with this appliance can turn the blowers ON or OFF and regulate the speed of the blowers in six 6 steps NOTE In the Normal T...

Страница 13: ...l CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD Per Manual a 3 5 Inches Water Column Maximum Nat Gas b 10 0 Inches Water Column Maximum L P Gas CYCLE BURNERS ON OFF FOR PROMPT IGNITION Per LIGHTING INSTRUCTIONS Burner must light IMMEDIATELY Flame must promptly light burne...

Страница 14: ...14 P a g e 85 03 00891 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED ...

Страница 15: ...al purchases that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts can be caused by over firing of your Mendota Fireplace Over firing above rated nameplate specification is as contrary to the manufacturer s instructions and may void this warranty This warranty may...

Страница 16: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com ...

Отзывы: