In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the
stove is installed to provide combustion air.  This is particularly necessary if the room is double-glazed or a flue draught
stabiliser is operating in the same room as the appliance. The provision of air supply to the stove must be in accordance with
current Building Regulations Approved Document J. An opening window is not appropriate for this purpose. Air inlets must
be positioned in such a way that they cannot be blocked. An air inlet may be a vent (the vent must be open and the capacity
for the vent sufficient when the stove is lit) .

There are no European rules regarding the minimum distance to non-flammable walls, Mendip Stoves recommend leaving

a gap of at least 100mm behind and to sides of stove.

Christon models  take all combustion air  from a single 80mm port at the rear of the stove, with the door closed the air port

supplies all combustion air for the appliance. This can be connected to the outside via a 80mm pipe so the appliance does
not draw air from the room. However Mendip stoves still recommends the use of an air brick  as laid out in document j for
when the stove is being reloaded.

T

he hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not independently

supported. The Christon 400 inset stove has been tested and are suitable to be installed on a 12 mm non combustible plate
such as  12 mm glass plates . Installation of all hearths should comply in size and construction so that it is in accordance with
the provisions of the current Building Regulations Approved Document J.

The clearance distances to combustible material beneath, surrounding or on the hearth and walls adjacent to the hearth

should comply with the guidance on the separation of combustible material given in Building Regulations Approved Document
J and also in these stove instructions.
If the stove is to be installed on a wooden floor, it must be covered with a non-combustible material at least 12 mm thick,
in accordance with Building Regulations Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to
each side measuring from the door of the combustion chamber.

HEARTH

COMBUSTION AIR

COMBUSTION CHAMBERS

Mendip Stoves are  fitted internally with vermiculite heat deflection panels and baffles, these panels are designed to ensure
the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles should not be removed
other than for cleaning the stove. Any defective panels should be replaced, small hairline cracks do need replacement and
can develop during long term use.  When refuelling  your stove place wood fuel into the chamber,  impact from logs can
cause  the heat deflection panel to crack

.

Connection to chimney

Mendip Christon is built  with a top flue outlet only, this can be altered  from vertical to a 30 degrees  connection by
removing  the top  collar and rotating the collar 180 degrees,. Care should be taken to ensure an airtight fit when refitting
collar and plate.This collar allows connection to either a masonry chimney or a prefabricated factory made insulated
metal chimney.

COMMISSIONING AND HANDOVER

Ensure loose parts  ( brick and grates) are fitted in accordance with the instructions  given in the instruction booklet. On
completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, a small fire may be
lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely into the atmosphere. Do not
run at full output for at least 24 hours.

On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the

customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used in the stove and
notify them to use only the recommended fuels for the stove. Advise the user what to do should smoke or fumes be emitted
from the stove.

The customer should be warned to use a fireguard to BS 8423:2002 in the presence of children, aged and/or infirm persons.

Содержание Christon 400 3 Sided Frame

Страница 1: ...1 OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Christon 400 Inset 3 Sided FRAME 4 Sided FRAME August 2016 ...

Страница 2: ...complied with when installing this appliance For further information on installing and using fireplaces and wood burning stoves please see the relevant building regulations These instructions cover the basic principals to ensure the satisfactory installation of your multi fuel stove although detail may need slight modification to suit particular local site conditions MODEL NAME Stove Height mm Sto...

Страница 3: ...ve must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove because this can cause the stove to emit fumes into the room Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the coarse of installation then please seek specialist guidance and use appropriate protec...

Страница 4: ...tove Any bend in the chimney or connecting flue pipe should not exceed 45 90 bends should not be used other than within 150 mm of stove rear flue outlet FLUE CHIMNEY CONNECTION TO STOVE Tested Gas flow rates flue gas temperatures Flue gas flow rate Wood coal Test flue gas temperature wood coal pascals of pressure Christon 400 4 0 4 7g sec 244 240deg C 12 pa Chimney Connection In order for the stov...

Страница 5: ...the appliance is installed on an unlined masonry flue Fit a non combustible closure plate to locate the first section of single wall flue pipe from the appliance to the old system Making the connection as with a flue liner system 4c Do not connect the system into large voids that could exist in older chimney systems If this is the case consider using a flue lining system or closure plate to improv...

Страница 6: ...nstructions The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove Distance to combustibles rear Distance to combustbles sides Distance to combustibles sides Convection models Suitable for 12mm non combustible floor plate Christon 200mm 200mm n a N a Mendip Stoves Chrstion 400 models are tested in accordance with EN 13240 Stove model Weight Nomina...

Страница 7: ...stalled on a wooden floor it must be covered with a non combustible material at least 12 mm thick in accordance with Building Regulations Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber HEARTH COMBUSTION AIR COMBUSTION CHAMBERS Mendip Stoves are fitted internally with vermiculite heat deflection panels and ba...

Страница 8: ...ST TIME Before lighting your stove for first time make sure you have read this manual fully and acquainted yourself with the controls of this appliance see page 8 The heat resistant paint on your stove will cure and harden the first time you light your appliance The curing process produces a good deal of smoke and odour it is therefore important that the first time you light your stove the room sh...

Страница 9: ...o position 2 when controls stops When burning coal use position 3 to position 4 When burning coal the primary air control drops to position 3 midpoint location operate and regulate your stove Primary air Pull out to open Wood coal Position 1 Min Position 3 Min Position 2 Max Position 4 Max Secondary air slide right to open Ash riddling arm To riddlie pull and push Door handle Starting point 1st ca...

Страница 10: ...ablished then close 6 The fire should now be fully established and burning brightly At this stage close secondary air control by 50 this is the operational setting For the stove to burn cleanly and efficiently plenty of secondary air is needed do not be tempted to shut the fire down too early as this may cause smoke At nominal heat output expect to refuel your stove once an hour Check load weights...

Страница 11: ...ns Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements Only specific SE models are suitable for smoke control areas see page 5 ...

Страница 12: ...efore refuelling riddle your stove with riddler open secondary air control fully open primary air control fully Open door and re load 1 1 kg of smokeless coal Close the door and leave the primary and secondary air controls open until fire is re established Maintain secondary air control at 100 and maintain primary air control to it operational position 100 open In the event of a chimney fire Close...

Страница 13: ... hot embers OVERNIGHT BURNING PERMANENT AIR VENT The stove requires a permanent air vent to the room This is to provide adequate air supply in order for the stove to operate safely and efficiently In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air This air vent should not ...

Страница 14: ... of secondary air may be insufficient c fire not hot enough 4 The stove fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 Smoke or odour a weak chimney draft b check for blockages in the flue pipe chimney c check the height of the chimney relative to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air ma...

Страница 15: ...ash pan drawer Lift and pull out of firebox chamber Take care to support ash pan during movement always wear a heat resistant glove Make sure the stove is completely cold before cleaning out ash embers can remain hot for over 24 hours Ash must be stored in a non combustible container and must not be mixed with other combustible waste Annual service The inside of the stove should be serviced cleane...

Страница 16: ...ves performance Do not throw away 8 Moisture absorbency bag LOOSE PARTS PIÈCES DÉTACHÉES STOVE PARTS COMBUSTION CHAMBER ASSEMBLY This section shows the parts contained in your stove each stove has over 80 spare parts and each part is detailed When new parts are required the section will allow spares to be recognised and ordered As a further source of reference please visit www eurostove co uk for ...

Страница 17: ...0 04 00 00 00 W13500 02 24 99 00 W10100 05 02 00 00 W90001 05 01 32 00 Complete brick set code W13500 02 00 99 00 W13500 02 44 00 00 W93500 05 08 00 00 Part Code Part Code Door Glass M10540 01 01 99 00 Ashpan W13500 03 00 00 00 Door rope seal W13500 06 02 00 00 Handle M10540 06 04 99 00 Glass rope seal M10510 01 02 01 00 Tool W13500 05 05 99 00 ...

Страница 18: ...up and remove Remove lower baffle brick slide baffle plate forward then allow rear of baffle to drop down until baffle is vertical turn baffle and remove from chamber This reveals inner baffle brick above Remove inner baffle brick by sliding out inner baffle support brackets on each side lower baffle to vertical position turn and remove from combustion chamber Remove base grate Slide up rear brick...

Страница 19: ...acuum out chamber and ash pan area before re installing bricks HOW TO REMOVE A VERMICULITE BRICK SET MONTAGE ET DÉMONTAGE DE L INTÉRIEUR When re installing base grate make sure lugs under the grate are in the quarter to three position and match the cutout in the base of the stove When installing riddling grate ensure riddling arm pin is placed in the hole in riddling grate ...

Страница 20: ...Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Distribué en France par la société Distributed in France and Benelux by Eurostove SAS Centre d Affaires Rue de L horlogerie BP 60011 62401 Bethune Cedex Contact eurostove fr www eurostove fr Part of Eurostove group ...

Отзывы: