12
Note: on cold days it maybe necessary to warm the flue using two firelighters.
1. Place a few smaller pieces of dry wood (kindling) in the stove on top of the nontoxic firelighters, place one or two small
dry split and small quantity of Smokeless coal.
2 Fully open the secondary air control above the stove door on right hand side. Fully open primary air control at base left
of stove. Pull open coal switch. Pull out riddling arm fully at base right of stove. The Uniq 35 stoves aircontrols are now
fully open.
3.Light the firelighters and push door to closed position and close handle to 1st position; this will allow a small gap in the
door for more air to be supplied to stove during ignition period.
4. When the flames are established and the fire is burning brightly load 1.1 kg of smokeless coal and close door latch to
position 2 fully closed. Once the fire is burning maintain the secondary air control 100%.
5 Now the fully established fire bed is burning brightly . Maintain primary air control at 100%, this is the
operational setting. For the stove to burn cleanly and efficiently primary air is needed, do not be tempted to shut the
fire down too early as this may cause smoke. At nominal heat output, expect to refuel your stove once every two hours.
Re-fueling solid fuel
To re-fuel your stove. Only refuel your stove when flames have died down and you have glowing embers.
Before refuelling riddle your stove with riddler , open secondary air control fully , open primary air control fully . Open
door and re load 1.1 kg of smokeless coal. Close the door and leave the primary and secondary air controls open until fire is
re-established. Maintain secondary air control at 100% and maintain primary air control to it operational position (100%
open).
In the event of a chimney fire: Close the air controls and the stove door, and call 999 or your local fire brigade.
If your stove is overheating close all air sliders and door , leave until the stove has returned to normal temperature.
The stove is only suitable for intermittent use only: do not run overnight or for long periods unattended.
Experience will determine the settings that produce best results. Use a flue thermostat to check the stove is not overheating.
Flue thermostats should be placed directly above collar of the stove on a non insulated section of pipe. (efficient operating
temperature range is between 100c and 200c) The stove will get very hot during use and due care must therefore be exercised.
Please use the glove and operating tool supplied when operating air controls and door.
SOLID SMOKELESS FUELS- Christon 400
models are suitable for use with good quality smokeless fuels and have been fully
tested to the relevant European standard. Only use registered smokeless fuels on this stove. Take special note of load
quantities in front of this book.(page 5)
HOUSE COAL AND PETROLEUM COKE ARE NOT SUITABLE FOR USE ON
THIS STOVE; ITS USE WILL INVALIDATE THE GUARANTEE.
LIGHTING THE STOVE - SOLID FUELS