![Member's Mark M3206ALP Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/members-mark/m3206alp/m3206alp_operators-manual_1769074015.webp)
USE AND CARE INSTRUCTIONS
Natural Gas Model only:
Connecting Natural Gas To Your Grill
WARNING
!
!
Check all connections for NG Leaks
Never
test for leaks with a flame. Prior to first use,
at the beginning of each season, you must check
for gas leaks. Follow these three steps:
Make a soap solution by mixing one part liquid
detergent and one part water.
Turn the grill Control Knobs to the full OFF
position, then turn the gas ON at source.
Apply the soap solution to all gas connections
indicated by the arrows. See
Fig. 3
. If bubbles
appear in the soap solution the connections
are not properly sealed. Check each fitting and
tighten or repair as necessary.
Figure 1
Figure 3
Figure 2
Gas Supply
Inside Wall
Outside Wall
Male Fitting
To Grill
Locking
Shut Off
Shut Off
Quick
Disconnect
Your natural gas grill is designed to operate on
natural gas only, at a pressure of 4" water column
(W.C.) with natural gas regulator. The gas pressure
Regulator supplied with this appliance must be
used. This Regulator is set for an outlet pressure
of 4" W.C.
Install a Shutoff Valve at the gas supply source
outdoors at a point after the gas pipe exits the
outside wall and before the quick-disconnect hose.
Or install it at the point before the gas line piping
Pipe sealing compound or pipe thread tape
resistant to the action of natural gas must be used
on all male pipe thread connections.
Disconnect your gas grill from fuel source when the
gas supply is being tested at high pressures. This
gas grill and its individual shutoff valve must be
disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is being
tested at low pressures. The grill must be isolated
from the gas supply pipe system by closing its
individual manual shutoff valve during any pressure
testing of the gas supply pipe system at pressures
equal to or less than 1/2 psi (3.5kpa).
Natural Gas Safety Instructions
Horizontal fitting
Hose, 12 ft./ NG
Swivel nut
enters the ground. See
Fig. 2
.
Gas Valve / Manifold Assembly
NG Regulator
Hose, 12 ft./ NG
If you have a gas leak that cannot be repaired
by tightening, turn off the gas at the source,
disconnect fuel line from your grill and call
1-800-770-9769
or your gas supplier for repair
assistance.
15
Connect the Swivel nut of the 12' Natural Gas
Hose to the horizontal fitting of NG Regulator as
shown in
Fig. 1
. Connect the other hose end
(male plug) to the gas supply line from house.
Also, read and follow all natural gas safety
instructions below.