M-WRG-S
Installation manual
M-WRG-K
5
Meltem Wärmerückgewinnung GmbH & Co.KG
Am Hartholz 4 D-82239 Alling [email protected] www.meltem.com
1.1. Assemble only with correct mounting elements
The mounting elements, which are included in the delivery, are to be installed on the exterior wall. Only use certified
mounting parts from the manufacturer!
1.2. Safety precautions during installation
•
Electrical connections may only be carried out by certified technicians.
•
Please pay attention to the safety precautions while working with power tools.
•
Please pay attention to the safety precautions while installing the mounting elements. Ensure that the
working area is secured in case of falling parts.
•
Ensure that there are no power lines running through the wall you plan to install the mounting elements.
1.3. Vapor barrier
In case you are installing the ventilation unit in a wall with a vapor barrier, the vapor barrier has to be properly
resealed as required by the manufacturer.
1.4. Warning: Operation with open fire places
During the planning and installation process of the ventilation system, the fireplace safety regulations (i.e.FeuVo)
have to be met! Before operating the M-WRG ventilation unit, the installation has to be discussed and approved by
the responsible official authorities and the chimney sweeper.The M-WRG ventilation units are only allowed to be
installed in living environments with open fireplaces, if:
1.
A simultaneous operation of open fireplaces that use liquid or gaseous fuel and the ventilation unit M-WRG is
prevented by safety equipment,
or
2.
The exhaust air of an open fireplace is monitored by safety equipment. In case the safety equipment is
triggered, the open fireplace or the M-WRG ventilation unit has to be turned off.
The M-WRG installation units are
not to be installed
, if the open fireplace is connected to a flue gas system with
multiple connections.
In order to operate the M-WRG ventilation units in accordance with regulations, exhaust air conducts of open
fireplaces have to able to be turned off by a shutoff device. In case of open fireplaces that use solid fuel, the shutoff
device has to be manually operable. The position of the shutoff device’s lever has to be clearly labeled, indicated
and recognizable.
1.5. Warranty
Improper installation invalidates the warranty. No warranty is offered for the installation and the correct
implementation of the installation.