- 37 -
Installation manual
M-WRG-II M
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L A T I O N & H E A T R E C O V E R Y
9.13
Cladding the installation kit and flat ductwork / flexible pipes on the inside
In this installation example, the inside
is cladded with OSB board and plaster-
board.
►
Make sure that the plaster cover
(item 1 in Fig. 33) is seated in the
wall box (item 2 in Fig. 33).
►
Make a cutout in the OSB board
(item 3 in Fig. 33) with the same
dimensions as the wall box (item 2 in
►
If necessary, make a cutout in the
OSB board (item 3 in Fig. 33) with the
same dimensions as the flat ductwork
elbow (item 4 in Fig. 33, only when
connecting a flat ductwork or flexible
pipe system).
► Make a cutout in the plasterboard (item 5 in Fig. 33) with the same dimensions as the
plaster cover (item 1 in Fig. 33).
► If necessary, make a cutout in the plasterboard (item 5 in Fig. 33) with the same
dimensions as the flat ductwork elbow (item 4 in Fig. 33, only when connecting a flat
ductwork or flexible pipe system).
► Place the OSB board (item 3 in Fig. 33) on the wall box (item 2 in Fig. 33) and fix it to
the frame construction.
► Align the cutout in the plasterboard (item 5 in Fig. 33) on the plaster cover (item 1 in
Fig. 33) and fix the plasterboard in position.
Fig. 33:
Cladding the installation kit and flat ductwork /
flexible pipes on the inside
1
2
3
4
5