Figure 2: Physical and Logical Link Indication LEDs

1.2

Switch Status Lights

The switch Status lights indicate whether the switch is receiving power from the chassis, and the 
state of the switch.

Figure 3: Indicator LEDs

Table 3 -  IOM states and LED configurations:

LED

Switch Status

Indication

Green

Status

OFF

OFF 

OFF

ON

OFF

Boot in Progress

Switch not ready

                       Blinking Blue

ON

BLINKING BLUE

The CMC is identifying

 the newly installed switch

ON

 ON BLUE 

Switch is on and operating Normally

ON

ON or BLINKING 

AMBER

Fault in System

Self-diagnosed

OFF

ON or BLINKING 

AMBER

Fault in System

CMC-detected

LED Name

Connection Status

Physical Link

 - Green 

Off – No Physical Link
ON – Physical Link

Data Activity

 - Yellow

Blinking – indicates Data Transfer
Constant on – indicates Link exists

 

 with no Data Transfer taking place
Off with green LED lit – indicates that

 

 the Subnet Manager may not be  running

The IO Module is on and 
ready when both the blue and 
green LEDs are lit. 

This LED can be blue or 
amber. A fault is indicated 
when the amber LED is blink-
ing. See Table 3. 

Содержание InfiniScale IV M3601Q

Страница 1: ...anox Technologies Third party information brought to you courtesy of Dell InfiniScale IV 16 16 Port 40Gb s InfiniBand Switch for Dell PowerEdge M1000e series Blade Enclosures User Manual PN M3601Q Rev...

Страница 2: ...U S A www Mellanox com Tel 408 970 3400 Fax 408 970 3403 Mellanox Technologies Ltd PO Box 586 Hermon Building Yokneam 20692 Israel Tel 972 4 909 7200 Fax 972 4 959 3245 NOTE THIS INFORMATION IS PROVID...

Страница 3: ...Module Blank From the Chassis 12 2 2 3 Installing the Mellanox M3601Q Switch Into the Dell Chassis 12 2 3 Power Connections and Initial Power On 12 2 4 InfiniBand Cable Installation 12 Chapter 3 Clust...

Страница 4: ...ces Mellanox Technologies Web pages http www mellanox com Dell Support Web pages http support dell com Conventions Throughout this manual the name M3601Q and the terms switch I O module and IOM are us...

Страница 5: ...Port 40Gb s InfiniBand Switch User Manual MellanoxTechnologies Rev 1 1 5 Revision History Table 2 Revision History Table Date Revision Description March 2009 1 1 Added Dell Logo November 2008 1 0 Ini...

Страница 6: ...comes pre installed with all necessary firmware and configured for standard oper ation within an InfiniBand fabric and requires an InfiniBand compliant Subnet Manager running from one of the hosts Al...

Страница 7: ...a valid physical connection to the other system switch or HCA port exists The yel low LED when lit indicates that the Subnet Manager is running and a valid data link exists The yellow LED illuminates...

Страница 8: ...G BLUE The CMC is identifying the newly installed switch ON ON BLUE Switch is on and operating Normally ON ON or BLINKING AMBER Fault in System Self diagnosed OFF ON or BLINKING AMBER Fault in System...

Страница 9: ...fore carrying on with installation procedures 2 1 Installation Safety Warnings 1 Installation Instructions 2 Over temperature 3 Stacking the Chassis 4 During Lightning Electrical Hazard Suitable elect...

Страница 10: ...connectors Refer to the cable manufacturer for special warnings and instructions When this product is mounted or serviced in a rack special precautions must be taken to ensure that the system remains...

Страница 11: ...gle slot and connected to a its corresponding fabric the ConnectX Mezzanine I O card must be installed in the corresponding fabric You must install a module in slots B1 C1 before installing a module i...

Страница 12: ...inst the bar 5 Push the lever on the latching mechanism up making sure that the latching mechanism catches the locking bar The lever should now be parallel to the front panel 6 Check the indicator lig...

Страница 13: ...port receptacle Both LED indicators will turn off when the cable is unseated Care should be taken not to impede the air exhaust flow through the chassis Note Cable lengths should be used which allow...

Страница 14: ...ble in MLNX_OFED to update firm ware for this switch It also can be downloaded from http www mellanox com Downloads Firmware Tools The latest firmware can be found at http www mellanox com Support Del...

Страница 15: ...eck I 32 I skip option set no report will be issued I I Bad Links Info I I No bad link were found I Stages Status Report STAGE Errors Warnings Bad GUIDs LIDs Check 0 0 Link State Active Check 0 0 Perf...

Страница 16: ...mlxburn with the LID retrieved in step 3 above to perform the In Band burning operation Burn the InfiniScale IV switch root mymach mlxburn d dev mst SW_MT48438_lid 0x0003 fw fw IS4 mlx qq I Querying...

Страница 17: ...for the InfiniBand connector does not come on 1 Check that both ends of the cable are connected 2 Check that the locks on the ends are secured 3 Make sure that the latest FW version is installed on b...

Страница 18: ...y Compliance InfiniBand QoS Management Auto Negotiation of 10Gb s 20Gb s or 40 Gb s 9 InfiniBand Virtual Lanes for all ports 8 Data transport lanes and 1 management lane Baseboard Performance and Devi...

Страница 19: ...This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interference to radio communications Op...

Страница 20: ...ation of Information and Communication Equipment requires EMC test ing and certification for many electronic products Korean EMC certifications are issued by Radio Research Laboratory RRL which is org...

Страница 21: ...L Module Reset 10 Vcc Rx 3 3 V Power supply receiver 11 SCL 2 wire serial interface clock 12 SDA 2 wire serial interface data 13 GND Ground 14 Rx3p Receiver Non Inverted Data Output 15 Rx3n Receiver I...

Страница 22: ...4 5 6 7 8 9 2 2 2 2 2 2 2 2 2 1 2 3 4 5 6 7 8 3 3 3 3 3 3 3 3 RX4p GND GND GND RX4n RX2p RX2n TX1n GND TX1p GND TX3n TX3p GND IntL ModPrsL VccTx Vcc1 LPMode 18 35 8 50 Top ResetL SDA SCL ModSelL RX3p...

Страница 23: ...tour des ouver tures de ventilation Le ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradations de biens Pendant un orag...

Страница 24: ...24 8 Elimination du mat riel 9 Codes lectriques locaux et nationaux L limination de ce mat riel doit s effectuer dans le respect de toutes les l gislations et r glementations nationales en vigueur Ce...

Страница 25: ...w hrleisten Das Chassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herunt erf llt kann es zu Verletzungen und Besch digungen an Ger ten f hren Arbeiten Sie w hrend eines Gewitter...

Страница 26: ...26 8 Ger teentsorgung 9 Regionale und nationale elektrische Bestimmungen Die Entsorgung dieses Ger ts sollte unter Beachtung aller nationalen Gesetze Bestim mungen erfolgen Dieses Ger t sollte unter B...

Отзывы: