background image

ConnectX®-3 Ethernet Single  and  Dual SFP+ Ports Mezzanine Card User Manual for Open Compute Project

Rev 1.9

Mellanox Technologies

19

1282

Length

0xfd

1283

Data

STR_ZERO

Reserved (0x00)

1536

VPD Keyword

RW

STR

Remaining read/write area

1538

Length

0xfd

1539

Data

STR_ZERO

Reserved (0x00)

1792

VPD Keyword

RW

STR

Remaining read/write area

1794

Length

0xfd

1795

Data

STR_ZERO

Reserved (0x00)

2048

VPD Keyword

RW

STR

Remaining read/write area

2050

Length

0xfd

2051

Data

STR_ZERO

Reserved (0x00)

2304

VPD Keyword

RW

STR

Remaining read/write area

2306

Length

0xfd

2307

Data

STR_ZERO

Reserved (0x00)

2560

VPD Keyword

RW

STR

Remaining read/write area

2562

Length

0xfd

2563

Data

STR_ZERO

Reserved (0x00)

2816

VPD Keyword

RW

STR

Remaining read/write area

2818

Length

0xfd

2819

Data

STR_ZERO

Reserved (0x00)

3072

VPD Keyword

RW

STR

Remaining read/write area

3074

Length

0xfd

3075

Data

STR_ZERO

Reserved (0x00)

3328

VPD Keyword

RW

STR

Remaining read/write area

3330

Length

0xfd

3331

Data

STR_ZERO

Reserved (0x00)

3584

VPD Keyword

RW

STR

Remaining read/write area

3586

Length

0xfd

3587

Data

STR_ZERO

Reserved (0x00)

3840

VPD Keyword

RW

STR

Remaining read/write area

3842

Length

0xfc

3843

Data

STR_ZERO

Reserved (0x00)

4095

Small Resource Type END 

Tag (0x11)

0x78

Table 6 - MCX341A-XC[AB]N VPD Layout

Offset 

(Decimal)

Item

Value

Format

Description

Содержание ConnectX-3 MCX341A-XCAN

Страница 1: ...www mellanox com ConnectX 3 Ethernet Single and Dual SFP Ports Mezzanine Card User Manual for Open Compute Project P N MCX341A XCAN MCX341A XCBN MCX342A XCAN Rev 1 9...

Страница 2: ...E CUSTOMER S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO S AND OR THE SYSTEM USING IT THEREFORE MELLANOX TECHNOLOGIES CANNOT AND...

Страница 3: ...Unified Extensible Firmware Interface UEFI 14 2 2 Power 14 2 3 Memory 14 2 3 1 System Memory 15 2 3 2 SPI 15 2 3 3 EEPROM 15 Chapter 3 Ethernet Mezzanine Card Installation 20 3 1 Hardware Requirements...

Страница 4: ...ible Connector 14 Figure 5 PCI Device 20 Figure 6 Device Manager 23 Figure 7 Support Download Assistant 26 Figure 8 Mechanical Drawing of the Dual port MCX342A XCAN Mezzanine Card 29 Figure 9 Mechanic...

Страница 5: ...evision History Table 6 Table 2 Documents List 8 Table 3 Single and Dual port 10 Gigabit Ethernet Adapter Card 10 Table 4 Jumper Configuration 15 Table 5 MCX342A XCAN VPD Layout 15 Table 6 MCX341A XC...

Страница 6: ...the Dual port MCX342A XCAN Mezzanine Card on page 29 and Figure 9 Mechanical Drawing of the Single port MCX341A XC AB N Mezzanine Card on page 30 September 2012 1 5 Added operational and non operatio...

Страница 7: ...anical Drawing of the Dual port MCX342A XCAN Mezzanine Card on page 29 Added Figure 9 Mechanical Drawing of the Single port MCX341A XC AB N Mezzanine Card on page 30 March 2012 1 1 Added Section 1 2 A...

Страница 8: ...ologies Firmware download web page http www mellanox com Support Download Center Document Conventions When discussing memory sizes MB and MBytes are used in this document to mean size in mega bytes Th...

Страница 9: ...ould first seek assistance through their reseller Firmware and Software Updates The Mellanox support downloader contains software firmware and knowledge database infor mation for Mellanox products Acc...

Страница 10: ...ied Extensible Firmware Interface UEFI support 1 1 Supported Network Protocol Standards 10 Gigabit Ethernet is an Ethernet network protocol standard for LANs specifying data transfer rate of 10Gb s Me...

Страница 11: ...ct Rev 1 9 Mellanox Technologies 11 1 3 Finding the MAC and Serial Number on the Mezzanine Card Each Mellanox Mezzanine card has a label on the print side that shows the card serial number and the car...

Страница 12: ...para la insta laci n Warnings in Spanish on page 37 1 Installation Instructions 2 Over temperature 3 During Lightning Electrical Hazard Read all installation instructions before connecting the equipme...

Страница 13: ...pment should be in accordance to all national laws and regula tions This equipment should be installed in compliance with local and national electrical codes Caution Use of controls or adjustment or p...

Страница 14: ...ards When connected to a PCIe Gen3 environ ment firmware configures the card to use 4 lanes upon bring up 2 1 3 I2 C compatible Interface A three pin header on the Mezzanine cards is provided as the I...

Страница 15: ...rates an EEPROM that is accessible through the I2 C compatible interface The EEPROM capacity is 4Kb The EEPROM is used for storing the Vital Product Data VPD The PCI VPD Vital Product Data layout for...

Страница 16: ...STR Asset Tag 123 Length 0x18 124 Data N A STR_SPC N A 148 VPD Keyword RW STR Remaining read write area 150 Length 0x69 151 Data STR_ZERO Reserved 0x00 256 VPD Keyword RW STR Remaining read write are...

Страница 17: ...xfd 2819 Data STR_ZERO Reserved 0x00 3072 VPD Keyword RW STR Remaining read write area 3074 Length 0xfd 3075 Data STR_ZERO Reserved 0x00 3328 VPD Keyword RW STR Remaining read write area 3330 Length 0...

Страница 18: ...th 15 8 MSB 0xF 112 VPD Keyword V1 STR EFI Driver version 114 Length 0x6 115 Data N A STR_SPC 121 VPD Keyword YA STR Asset Tag 123 Length 0x18 124 Data N A STR_SPC N A 148 VPD Keyword RW STR Remaining...

Страница 19: ...Data STR_ZERO Reserved 0x00 2560 VPD Keyword RW STR Remaining read write area 2562 Length 0xfd 2563 Data STR_ZERO Reserved 0x00 2816 VPD Keyword RW STR Remaining read write area 2818 Length 0xfd 2819...

Страница 20: ...entify the Card in Your System 3 3 1 On Windows 1 Open Device Manager on the server Click start Run and then enter devmgmt msc 2 Expand System Devices and locate your Mellanox ConnectX 3 Mezzanine car...

Страница 21: ...lla nox Technologies 3 4 Cables and Modules The SFP port can connect to the Ethernet through both direct attach cables and stand alone transceivers with optical cables SFP transceiver modules are avai...

Страница 22: ...rmation run Example 4 1 2 Windows For Windows download the MLNX EN Ethernet driver Download this package from the Mel lanox web site at http www mellanox com Products Software Ethernet Drivers Connect...

Страница 23: ...nox Technologies 23 Figure 6 Device Manager Step 2 Right click a Mellanox ConnectX 3 Ethernet adapter under Network adapters list and left click Properties Step 3 Select the Information tab from the P...

Страница 24: ...abric provides all of the basic NIC functionality plus RDMA over Converged Ethernet RoCE RoCE utilizes advances in Data Center Bridging DCB to enable efficient and low cost implementations of RDMA ove...

Страница 25: ...the PSID and firmware version a Install the MFT package The package is available at http www mellanox com Products Software Ethernet Drivers Firmware Tools Make sure to download the package correspon...

Страница 26: ...ollows a Download the firmware image zip file from the Download Center see Step 2a above e Unzip the firmware image f Burn the firmware image Enter g Reboot the computer h Enter mst start i Verify tha...

Страница 27: ...wer PCIe x4 Gen3 Passive Cables 3 95W PCIe x8 Gen2 Passive Cables 4 97W Max Power PCIe x4 Gen3 Passive Cables 5 33W PCIe x8 Gen2 Passive Cables 6 24W Temperature Operational 0 C to 45 C Non operationa...

Страница 28: ...Cables 4 79W Max Power PCIe x4 Gen3 Passive Cables 5 10W PCIe x8 Gen2 Passive Cables 5 91W Temperature Operational 0 C to 45 C Non operational 0 C to 70 C Humidity 90 relative humiditya a For both ope...

Страница 29: ...r Manual for Open Compute Project Rev 1 9 Mellanox Technologies 29 A 3 Board Mechanical Drawing and Dimensions Figure 8 Mechanical Drawing of the Dual port MCX342A XCAN Mezzanine Card 42 05 All dimens...

Страница 30: ...nical Drawing of the Single port MCX341A XC AB N Mezzanine Card 42 05 A 4 Regulatory Statements For regulatory statements for all ConnectX 3 cards please refer to http www mellanox com related docs us...

Страница 31: ...Pinout Table 9 I2C compatible Connector Pinout Connector Pin Number Signal Name 1 SPSDA 2 SPSCL 3 GND B 2 PCI Express x4 Connector Pinout The Mezzanine cards use a standard PCI Express x4 Mezzanine c...

Страница 32: ...Rev 1 9 Mellanox Technologies 32 Figure 11 PCIe Connector Pinout...

Страница 33: ...ConnectX 3 Ethernet Single and Dual SFP Ports Mezzanine Card User Manual for Open Compute Project Rev 1 9 Mellanox Technologies 33 B 3 SFP Pinout Figure 12 SFP Cage Pinout...

Страница 34: ...bon coulement de l air laissez au moins 8 cm 3 pouces d espace libre autour des ouver tures de ventilation Pendant un orage il ne faut pas utiliser le mat riel et il ne faut pas brancher ou d branche...

Страница 35: ...imaler Umgebungstemperatur erforderlich Au erdem sollten mindestens 8 cm 3 in Freiraum um die Bel ftungs ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten Arbeiten Sie w hrend eines Gewi...

Страница 36: ...Rev 1 9 Mellanox Technologies 36 Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards ICE 60 825 1 1993 A1 1997 A2 2001 und EN 60825 1 1994 A1 1996 A2 2001...

Страница 37: ...Adem s para garantizar una circulaci n de aire adecuada se debe dejar como m nimo un espacio de 8 cm 3 pulgadas alrededor de las aberturas de ventilaci n No utilizar el equipo ni conectar o desconect...

Отзывы: