FOCKE MELER GLUING SOLUTIONS
4-6
MELTER OPERATION
ºC
ºC
To select the function to be programmed, press ‘up-down’ arrow on the left
side of the panel (1), to advance through the various functions. Once selected,
the buttons up and down modify the value. Pressing the arrow ‘up-down’ on
the right side of the panel (2) modify the value. Pressing the arrow ‘down’ (on
the left side) again the data is stored and passed to the next function.
To exit the special menu press the ‘up’ arrow (on the left side) at any time.
Programming process
1. Simultaneously press the buttons with the clock symbol and the down
arrow to enter the special menu.
The choice of temperature display units (°C or °F) will appear on the
display.
2. Select the desired value using the up-down arrow under the display.
3. Use the up arrow for element selection to move to the next display
where the overheating symbol appears.
4. Select the desired value (between 10 and 25) using the up-down arrow
under the display.
The value shown corresponds to the increase in real temperature
allowed over the set point temperature without activating the alarm
message.
5. Use the up arrow for element selection to go to the next display where
the standby function symbol appears.
6. Use the up-down arrow under the display to select the desired value
(between 25 and 55).
The value shown corresponds to the percent decrease in the real
temperature compared to the set point temperature that will occur
when this function is activated.
7. Use the up arrow for element selection to go to the next display where
delay time value appears.
8. Use the up-down arrow under the display to select the desired value
(between 0 and 60 min).
9. Use the up arrow for element selection to return to the initial
parameter.
For any parameter, the down arrow for element selection may be used to exit
the special menu and display the tank temperatures once again.
To record any parameter, you must always move to the next parameter, using
the right arrow.
ºC
ºC
11
22
_
_
_
_
_
_
10
10
_
_ _ _ _ _
25
25
00
00
tt
Содержание Cantho
Страница 1: ...ADHESIVE MELTER CANTHO INSTRUCTIONS MANUAL MA 5168 ENG 251019 GLUING SOLUTIONS ...
Страница 38: ...FOCKE MELER GLUING SOLUTIONS 4 14 MELTER OPERATION This page is intentionally left blank ...
Страница 44: ...FOCKE MELER GLUING SOLUTIONS 5 6 MAINTENANCE This page is intentionally left blank ...
Страница 48: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 49: ...ELECTRICAL DRAWINGS 7 1 MA 5168 ENG ADHESIVE MELTER CANTHO 7 ELECTRICAL DRAWINGS ...
Страница 50: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 52: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWINGS This page is intentionally left blank ...
Страница 62: ...FOCKE MELER GLUING SOLUTIONS 9 10 SPARE PART LIST This page is intentionally left blank ...
Страница 64: ......