GD-5610v1
Instructions Manual
6.Connection
6-1.Overview of Connection Configuration
GD-5610v1
● Connect only one motor to one driver.
● Use twisted pair wire for the CW/CCW input signal line.
● Provide shielding for the signal line where considerable noise is generated.
● Use the wire material of the characteristic that is difficult to burn.
● Provide ferrite core for the motor line if it generates significant noise.
〔Example configuration〕
The metallic enclosure and shielded wires and ferrite core work to shield noise.
CWP
J1
CW+
1
R.GND
User
controller
CCWP
+COM
+COM
R.GND
2
3
4
5
6
7
8
9
10
11
12
C.S
O.H.A
P.O
M.F
CCWP
CWP
CW-
CCW+
CCW-
M.F+
M.F-
C.S+
J3
P.O+
O.H.A+
C.S-
J2
1
2
3
5
3
4
1
2
Protective earth
terminal for the
equipment (PE)
(O.75mm
2
or more)
Motor
Single-phase 100-115V
N
L
Twisted
pair wire
Single-phase 100-115V
P.O-
O.H.A-
User
controller
Driver
Metal Enclosure
Metal Enclosure
Grounding
Shield
Metal Enclosure
Motor
Ferrite core
Grounding
Grounding
-22-