GD-5510-01
Instructions Manual
4.Function Set-up by Use
4-1.Setting MOTOR SELECT switch
Erroneous setting may cause burn on the
skin due to overheating of the motor.
Ensure correct setting.
The MOTOR SEL switch is turned to the setting
corresponding to the motor in use.
Set this switch with power OFF.
The switch is factory-set to [10L].
(1) Turn power [OFF].
(2) Set the MOTOR SEL switch [10L/5L] to the setting specified in the table
"10-5. Applicable Motors."
4-2.Setting HIGH-SPEED POWER OUTPUT SELECT switch
HIGH-SPEED TORQUE is set up with the POWER SEL switch.
There are four different types of torque characteristics.
The switch is factory-set to [LP,L].
(1) Set the POWER SEL switch [HP/LP][H/L] to the torque characteristic required.
● Relationships of the switch setting and heat generation by the motor and
HIGH-SPEED TORQUE.
● Select the switch [HP,H](ON,ON) if HIGH-SPEED TORQUE is required, and the
switch [LP,L](OFF,OFF) if not, in order to control heat generation by the motor.
The maximum setting for each motor are given in the table
"10-5. Applicable Motors". Be sure to select the maximum setting for each motor,
or low setting.
● Selecting one of the switch setting types leads to power demand as shown below:
(Factory setting)
LP,H
HP,H
(with DRIVE I.SEL No.F set up)
Inputting single-phase 100V
Switch setting
420VA
LP,L
180VA
240VA
360VA
HP,L
CAUTION
Heat generated by the motor
HP,H
LP,L
Heat Generation Model
Motor rotation
speed
HP,H
LP,L
Torque
Torque Model
Motor rotation
speed
-15-