Page 20
The displays shows the maximum values for pressure and temperature achieved. If the user has connected
a printer, it will print out a report.
3.8 Interfacing a printer _____________________________________________________
The Vacuklav
®
31 unit has been provided with a serial printer interface: this interface enables connection of
the MELAprint
®
40 (dot-matrix printer) as an option. The user can then print out reports of the programs
executed.
If the customer purchases the Vacuklav
®
31 with printer or without the printer, and later decides to retrofit by
connecting the MELAprint
®
40, the printer interface on the Vacuklav
®
31 must be enabled before the printer
can be interfaced.
Installation:
The cables contained in the printer package as delivered are for electrical power and data transfer. Plug in
the power cable to the jacks for power [75]. Plug in the cable as interface, at the socket [74] on the rear of
the autoclave, and at the printer in the socket provided.
Make sure that enough paper has been installed in the printer.
In its initial operating state printer is "Not installed." To install it, please proceed as follows:
1. Switch off the Vacuklav 31.
2. Press and hold down the buttons "+" and "-" [17] and the program selector [18] all at the same time, and
switch the power switch [15] on.
3. You are now in the service program (you see "Record output"). Press button "+" [17] until you reach "Ex-
ternal printer."
4. Acknowledge by pressing the button "Program select" [18]. When you press "start/stop" [19], you have
installed the printer.
3.9 VDE stipulations ________________________________________________________
According to VDE stipulations presently valid, this device is not suitable for application in potentially explo-
sive environments. This device may be serviced only by the manufacturer, or by personnel expressly au-
thorized by the manufacturer (i.e., a specialist dealer, or the MELAG Customer Service Department).
3.10 Safety instructions _____________________________________________________
After opening the door of the autoclave, do not touch exposed hot metal parts.
These parts can cause
burns to the bare skin.
Use tray lifter to take out trays which are still hot. Use suitable hand protection
to remove other sterilization containers.
Do not open the door until the system has signaled that the pressure in the chamber has normalized.
This is signaled by a "0" in the display. The autoclave chamber can release small amounts of residual
steam when the door is opened.
Only persons authorized by the MELAG company, who use original spare parts in their service work, may
service this device.
Do not open the enclosure of the autoclave before unplugging the power plug from its socket.
When installing an external water-treatment unit, it is absolutely necessary to install the overflow system
and to test it by performing a trial run according to the instructions given above, to ensure that it in fact
functions properly.
Empty the water storage tank before moving the autoclave.
Do not move the autoclave when it contains water.
Do not use this autoclave to sterilize liquids.