Condition 1: The contact is now
closed
4.
Slowly push the switch contact
in the direction of flow until the
contact opens
Condition 2: The contact is now
open
5.
Slowly push the switch contact
in the direction of flow until the
contact closes, then keep
pushing slowly in the direction of
flow until the contact opens
6.
Tighten the set screws of the
switch contact (Fig. 33/1) using
a flat-bladed screwdriver. When
doing so, observe the correct
tightening torque of the screws.
ð
The set switch point corre-
sponds to the switch-off
point of the switch contact
by decreasing flow.
Setting the switch point of a non-
installed device
Fig. 34: Loosen set screws
1.
Loosen the set screws of the
switch contact (Fig. 34/1) using
a flat-bladed screwdriver
2.
Using a non-magnetic rod (e.g.
test rod), move the float to the
point on the measuring scale
that corresponds to the flow rate
to be monitored. The top edge
of the float is the read-off point
3.
Slowly push the switch contact
in the opposite direction of flow
up to the stop
Operation
Setting the switch point
03.09.2018
DWG Module BASICS Flow Monitor