17th June 2020

Meinberg Funkuhren GmbH & Co. KG

Содержание MicroSync

Страница 1: ...TECHNICAL REFERENCE microSync RX101 AD10DC20 17th June 2020 Meinberg Funkuhren GmbH Co KG ...

Страница 2: ......

Страница 3: ...4 Time Code AM modulated Output 18 5 5 Frequency Synthesizer Output 19 5 6 RS 232 COMx Timestring 19 5 7 Status Indicators 20 5 8 USB Interface 21 5 9 LAN Network Interfaces 21 5 10 DMC X2 Terminal Connector 22 5 11 Fiber Optic Programmable pulse Output 23 5 12 DMC X1 Terminal Connector 24 6 GNSS Satellite Navigation 26 6 1 Time Zone and Daylight Saving 27 7 Mounting the GPS Antenna 28 7 1 Antenna...

Страница 4: ...kuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2020 06 17 Manual Version 1 02 microSync Date 17th June 2020 1 ...

Страница 5: ...ifferent receiver variants e g the 72 channel GNSS receiver for GPS Galileo GLONASS and BeiDou The sync optimized operating system supports NTP PTP IEEE 1588 and a variety of protocols for management tasks Product Highlights Powerful IEEE 1588 PTP Time Server incl IEC IEEE 61850 9 3 IEEE C 37 238 High performance S NTP server Redundant power supply Different Oscillator options for advanced holdove...

Страница 6: ...age Temperature 30 70 C Humidity 5 to 95 non condensing 40 C Operating Altitude up to 4 000 m 13 123 ft above sea level Atmospheric Pressure 615 to 1 600 hPa Physical Dimensions 483 mm 19 inch 465 mm 18 31 inch 31 8 mm 1 25 inch 43 mm 1 68 inch 444 mm 17 50 inch 236 mm 9 30 inch 270 mm 10 63 inch 248 mm 9 77 inch microSync Date 17th June 2020 3 ...

Страница 7: ...ou may only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imminently hazardous situation with a high risk level This notice draws attention to an operating procedure or similar proceedings of which a non observance may result in serious personal injury or dea...

Страница 8: ...siko eines elektrischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht heiße Oberfläche Caution hot surface IEC 60417 6056 Vorsicht Gefährlich sich bewegende Teile Caution moving fan blades IEC 60417 6172 Trennen Sie alle Netzstecker Disconnection all power plugs IEC 60417 5134 Elektrostatisch gefährdete Bauteile Electrostatic Sensitive Devices IEC 60417 6222 Information generell ...

Страница 9: ... be used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the installer Non observance of these instructions can lead to a reduction in the safety of this device Please keep this manual in a safe place This manual is intended exclusively for electricians or ...

Страница 10: ... soiling additional measures e g Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait until the unit is temperature controlled and absolutely dry before operating it When unpacking setting up and before operating the equipment be sure to read the information on...

Страница 11: ...work properly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure that all connections are secure Faulty shielding or cabling will endanger your health electrical shock and may destroy other equipment Ensure that all necessary safety precautions have been taken...

Страница 12: ...hat the mains socket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside the assembly group the device must be disconnectable from the power supply in accordance with the provisions of IEC 62368 1 e g by the primary line protection Installation and disassembly of the pow...

Страница 13: ... dusty as there is a danger of overheating during operation Disturbances during operation can result Normal Operation The normal operation and the observance of the EMC limits electromagnetic compatibility are only ensured if the housing cover is properly installed and when the doors are closed cooling fire protection shielding against electrical magnetic and electromagnetic fields Switch off in f...

Страница 14: ... to considerable risks for the user and result in a loss of warranty as well as an exclusion of liability Danger due to moving parts keep away from moving parts Device parts can become very hot during operation Do not touch these surfaces If necessary switch off the unit before installing or removing any equipment and allow it to cool down 4 7 Handling Batteries CAUTION The lithium battery on the ...

Страница 15: ...pare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when working with such assemblies which you attach to an unpainted non conductive metal part of the system Use only tools and devices that are free from static electricity Transporting Assemblies Assemblies may only be ...

Страница 16: ...he WEEE Directive The product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country specific return and collection systems available to you or contact Meinberg The withdrawal may be refused in the case of waste equipment which presents a risk to human health or safety...

Страница 17: ...10 MS Power U 100 V 240 V N U 90 V 254 V max I 1 0A N f 50 60Hz N U 100 V 200 V N U 90 V 240 V max I 0 6A N A A B B C 1 Interrupt the power supply of the power supply unit by pulling off the protective plug of the power cable 2 Remove the 5 pin DFK jack from the power supply after dissolving the two clamping screws B with the slot screwdriver 3 Then loosen the two Torx screws A of the power supply...

Страница 18: ...er Maximum Power Pmax 50 W Max Heat Emisson Etherm 180 00 kJ h 170 61 BTU h N L AD10 MS Power U 100V 240V N U 90V 254V max I 1 0A N f 50 60Hz N U 100V 200V N U 90V 240V max I 0 6A N N L AD10 MS Power U 100V 240V N U 90V 254V max I 1 0A N f 50 60Hz N U 100V 200V N U 90V 240V max I 0 6A N WARNING This equipment is operated at a hazardous voltage Danger to life due to electrical shock Only qualified ...

Страница 19: ... 4 VIN 5 not connected Input Parameter Nominal Voltage Range UN 24 48 V Maximum Voltage Range Umax 20 60 V Nominal Current IN 2 10 A Output Parameter Maximum Power Pmax 50 W Max Heat Emission Etherm 180 00 kJ h 170 61 BTU h U 24 48V N U 20 60V max I 2 10A N Power DC20 MS 16 Date 17th June 2020 microSync ...

Страница 20: ... frequencys are transfered via the antenna cable Power Supply 15 V DC 100mA from receiver via the antenna cable Antenna GNSS IF 15 V WARNING Working on the antenna system during thunderstorms Danger to life due to electrical shock Do not carry out any work on the antenna system or the antenna cable if there is a risk of a lightning strike Do not carry out any work on the antenna system if the safe...

Страница 21: ...dle All Sync Time Sync Position OK DCF77 Marks Pulse Per Hour Pulse Per Min DCLS Time Code Serial Time String Synthesizer Frequency PTTI 1PPS PP 1 Out PP 2 Out 5 4 Time Code AM modulated Output Signal outputs Unbalanced sine wave signal Signal level 3 Vpp 1 Vpp MARK SPACE into 50 Ohm Carrier frequency 1 kHz IRIG B Connection type BNC female Cable shielded coax line TC AM Out 18 Date 17th June 2020...

Страница 22: ...nto 50 Ω Connection type BNC female Cable shielded coax line F Synth Out 5 6 RS 232 COMx Timestring Data transfer serial Baudrate framing 19200 8N1 default Time string Meinberg Standard default Assignment Pin 2 RxD receive Pin 3 TxD transmit Pin 5 GND ground Connector 9pin D SUB male Cable data cable shielded PC connector 1 1 COM 0 microSync Date 17th June 2020 19 ...

Страница 23: ... green all monitored network interfaces are connected Link up red at least one of the monitored network interfaces is faulty A Alarm off no error red general error REC Fail red no synchronization Ant red no synchronization resp no antenna connected or short circuit on the antenna line green antenna connected and clock is synchronized Nav green positioning complete Init blue initialisation phase gr...

Страница 24: ...abit Ethernet GbE 100 1000 MBit SFP LAN 0 1 Management NTP 10 100 1000Mbit RJ45 or 1000FX LAN 2 3 Management NTP 10 100 1000Mbit RJ45 or 1000FX PTP capable LAN 0 LAN 2 LAN 1 LAN 3 Recommended and tested Transceivers from other Vendors MULTI MODE AVAGO AFBR 5710PZ FINISAR FTLF8524P3BNL SINGLE MODE AVAGO AFCT 5710PZ FINISAR FTLF1318P3BTL RJ 45 AVAGO ABCU 5740RZ FINISAR FCLF8521P2BTL microSync Date 1...

Страница 25: ...0mA short circuit proof TCA Time Code Amplified DCLS output with large output current Pin 9 PP 5 program pulse optocoupler Pin 10 GND ground Pin 11 GND ground Pin 12 GND ground Pin 13 GND ground Pin 14 TC In Time Code DCLS TTL isolated Pin 15 not used Pin 16 not used Status LEDs PP 5 PP 8 Status of Pulses Out Status PP 9 8 16 1 X1 9 8 16 X2 1 9 8 16 1 5 6 7 8 To the X2 device connection 16 pin soc...

Страница 26: ...e Pulse outputs Pulse Per Second Cyclic Pulse Single Shot Timer Idle All Sync Time Sync Position OK DCF77 Marks Pulse Per Hour Pulse Per Min DCLS Time Code Serial Time String Synthesizer Frequency PTTI 1PPS PP 7 PP 8 Fiber Optic Out ATTENTION Unused connectors of optical interfaces should always be provided with a protective cap The optical interface contains a light emitting diode LED microSync D...

Страница 27: ...rror Relay common Pin 9 not used Pin 10 not used Pin 11 PP 1 programmable pulse Pin 12 PP 2 programmable pulse Pin 13 PP 3 programmable pulse Pin 14 PP 4 programmable pulse Pin 15 not used Pin 16 REL NC Error Relay normally closed Status LEDs PP 1 PP 4 Status of the programmable Pulses Out Status PP 9 8 16 1 9 8 16 1 X1 9 8 16 X1 1 Zum X1 Geräteanschluss 16 pol Buchse mit Klammer Kabeleingang 1 2 ...

Страница 28: ...tor has a potential free contact which is controlled directly by the used reference clock GPS GNS GNS UC Normally when the reference clock has synchronized the the relay contact NO switch to active If the reception is disturbed or the device is switched off the relay contact NC is active Technical Specification Switching Voltage max 60 V DC Switching Current max Imax 400mA Switching Load max 24 W ...

Страница 29: ...eters must be evaluated to compute the receiver s position and clock offset almanac parameters are used to check which satellites are in view from a given receiver position at a given time Each satellite transmits its own set of ephemeris parameters and almanac parameters of all existing satellites GPS was installed by the United States Department of Defense and provides two levels of accuracy The...

Страница 30: ...e scale since GPS was initiated in 1980 The current number of leap seconds is part of the navigation message supplied by the satellites so the internal real time of the GPS180 is based on UTC time scale Conversion to local time and annual daylight saving time can be done by the receiver s microprocessor if the corresponding parameters are set up by the user microSync Date 17th June 2020 27 ...

Страница 31: ... cable between antenna and receiver depends on the attenuation factor of the coaxial cable Up to four GPS180 receivers can be run with one antenna downconverter unit by using an optional antenna splitter The total length of an antenna line from antenna to receiver must not be longer than the max length shown in the table below The position of the splitter in the antenna line does not matter The op...

Страница 32: ...28ft max Cable lenght m ft used for receiver type RG58 CU 5 0 2 17 300 984 GPS GNS UC PZF RG213 10 3 0 41 7 700 2297 GPS GNS UC H155 5 4 0 21 9 1 70 230 GNM GNS H2010 Ultraflex 7 3 0 29 5 8 150 492 GNM GNS Further values can be found in the data sheet of the cable used microSync Date 17th June 2020 29 ...

Страница 33: ...racket Normally you connect the antenna converter directly with the antenna cable to the system GPS Antenna free view to the sky Cable Slot N Norm female N Norm male N Norm male N Norm female N Norm female N Norm male Meinberg GPS N Norm male female or BNC male female as short as possible Ground lead to PE rail Protective Earth Cable ca 1 5 mm Ø fastened at the surge protector 30 Date 17th June 20...

Страница 34: ...istributions include Ubuntu Mint Linux Debian SUSE Linux CentOS and others The software is delivered on the USB stick included in the scope of delivery and does not need to be in stalled or copied on the PC The Meinberg Device Manager can be started directly from the USB data carrier The computer must be connected to the network in which the microSync system is connected The software is downloadab...

Страница 35: ...user name with which the Meinberg Device Manager should authenticate itself to your Meinberg system Password enter a password with which Meinberg Device Manager should authenticate itself to your Meinberg system Silent Login you have the possibility that the Meinberg Device Manager will not ask for your username and password every time you log in Changing your Network Password To change the passwo...

Страница 36: ...our Mein berg module Then confirm the entry with Next to continue Hostname Enter any host name for your system or leave the field blank Then confirm the entry with Next to continue Static IP or DHCP In the next step you can determine whether you want to enter the IP address manually or whether a DHCP server should assign the IP address automatically Static IP Enter the IP address netmask gateway a...

Страница 37: ... outputs PP 1 PP 8 DC insulated by optocouplers UCEmax 55 V ICmax 50 mA Ptot 150 mW Viso 5000 V pulse delay ton e g 20 µsec IC 10mA toff e g 3 µsec IC 10mA change of second P_SEC TTL level change of minute P_MIN TTL level Accuracy after synchronization and 20 minutes of operation of Pulses OCXO SQ MQ HQ DHQ better than 50 nsec better than 2 µsec during the first 20 minutes of operation Frequency O...

Страница 38: ... ports Baud Rate 300 600 1200 2400 4800 9600 19200 Baud Framing 7E1 7E2 7N2 7O1 7O2 8E1 8N1 8N2 8O1 default setting COM0 19200 8N1 Meinberg Standard time string per second Time Code Outputs Unbalanced modulated sine wave signal 3 Vpp MARK 1 Vpp SPACE into 50 ohm DCLS signal TTL into 50 ohm active high or low microSync Date 17th June 2020 35 ...

Страница 39: ...ES IPv4 IPv6 IEEE 1588v2 Default Profile NTPv3 NTPv4 IEEE C 37 238 2011 Power Profile PTPv1 PTPv2 IEEE C 37 238 2017 Power Profile IEC 62439 3 PRP IEC IEEE 61850 9 3 Power Utility Profile DHCP DHCPv6 Enterprise Profile DSCP ITU T G 8265 1 ITU T G 8275 1 ITU T G 8275 2 Telecom Profile IEEE 802 1q VLAN filtering tagging SMPTE ST 2059 2 Broadcast Profile IEEE 802 1p QOS IEEE 802 1AS TSN AVB Profile S...

Страница 40: ...um polybrominated biphenyls PBBs and polybrominated diphenyl ethers PBDEs Bis 2 ethylhexyl phthalat DEHP Benzylbutylphthalat BBP Dibutylphthalat DBP Diisobutylphthalat DIBP above the legal threshold WEEE status of the product This product is handled as a B2B Business to Busi ness category product In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer Any trans...

Страница 41: ...htlinien übereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives RED Richtlinie ETSI EN 303 413 V1 1 1 2017 06 RED Directive 2014 53 EU EMV Richtlinie Draft ETSI EN 301 489 1 V2 2 0 2011 09 EMC Directive Draft ETSI EN 301 489 19 V2 1 0 2011 09 DIN EN 61000 6 2 2005 2014 30 EU DIN EN 61000 6 3 2007 A1 2011 DIN EN 55032 2015 DIN ...