SCG Configuration via Web Interface
(Firmware version 6.19 or later)
If the SCG operates in an IMS system, the module can be easily configured via the web interface then.
Configuration Sample: SCG Out 3
In the "IO Configuration" menu each output frequency can be adjusted seperately. In the figure above the
following value is set:
Frequency Out 3 = Base Frequency * Scale
Frequency Out 3 = 44,1 kHz * 1/4
Frequency Out 3 =
11,025 kHz
52
Date: 9th June 2016
LANTIME IMS-M500