12 Attachment: Technical Information
BPE - Backplane Port Expander (Frontend)
Output Signals:
fixed:
10MHz, PPS, IRIG DCLS, IRIG AM, 2,048 MHz,
PPOs (selectable via receiver)
Power Requirements:
5 V +-5%, 150 mA / BNC
5 V +-5%, 150 mA / FO
Status Indicators
LED St:
BPE status
LED In:
Status of the backplane’s output signals
LED A:
BPE status - output signals (1 + 2)
LED B:
BPE status - output signals (3 + 4)
Initialisation:
LED St: blue until USB is configured
LED In - LED B: off until USB is configured
USB is configured:
LED St: blue
LED In - LED B:
0,5 sec. red -> 0,5 sec. yellow ->
0,5 sec. green -> 0,5 sec. off
Normal Operation:
LED St. + LED In: green
LED A: green, if the desired signal is present
on output 1 and output 2
LED B: green, if the desired signal is present
on output 3 and output 4
Figure right: BPE Frontend
BPE-1000
Standard outputs - BNC female:
PPS, 10MHz, TC DCLS and TC AM
BPE 5000
Fiber Optic ST-Connectors
PPS, 10MHz, TC DCLS und TC AM
LANTIME IMS-M500
Date: 9th June 2016
33