7 Configuration of the IMS-PIO180
7 Configuration of the IMS-PIO180
This chapter explains how to put a IMS-PIO180 into operation via the web interface.
7.1 Menu IO Config
In the "IO Config" menu of the web interface, each port of the PIO180 can be set separately to "Input"
or "Output. To use the individual ports in
SyncMon
, the direction "Input" must be selected.
Directions:
"Output"
In this mode either the PPS or the 10 MHz of the reference clock will be issued.
"Input"
The input signal is compared with either the PPS of the system or the 10 MHz of
the reference clock. The offset values are displayed in the submenu "status" or can
be used as node in the SyncMon.
Configuration
1.
Open the menu
"I/O configuration"
2.
Open the submenu
"Configuration of the outputs"
3.
Select the PIO180 module you want to configure
4.
Select the desired direction in the tab of the port to be configured
IMS-PIO180 Setup Guide
Date: 6th May 2020