Meinberg IMS-GNM181 Скачать руководство пользователя страница 1

MANUAL

IMS-GNM181 Setup Guide

Hot-Plug Module

25th February 2020

Meinberg Funkuhren GmbH & Co. KG

Содержание IMS-GNM181

Страница 1: ...MANUAL IMS GNM181 Setup Guide Hot Plug Module 25th February 2020 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...able IMS Modules 12 6 2 Replacement or Installation of a Hot pluggable IMS Module 13 6 3 Installation GNSS Multiband Antenna 14 6 4 Connecting the System 18 7 Configuration of GNSS Receiver 19 7 1 Clo...

Страница 4: ...kuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2020 02 25 IMS GNM181 Setup...

Страница 5: ...ell as the installation of the coaxial cable Furthermore it describes the parameters that have to be configured in the web interface for a quick start of your product The LTOS7 manual provides a compl...

Страница 6: ...end power supplies back to the manufacturer for maintenance Exchange of hot swap components Ensure that components which will be replaced during operation always be treated with the utmost care Avoid...

Страница 7: ...f high voltage devices 3 2 Cabling WARNING DANGER TO LIFE BY ELECTRICAL SHOCK NO LIVE WORKING Wiring or any other work done the connectors particularly when connectors are opened may never be carried...

Страница 8: ...ng or installing components This could result in a loss of grounding protection from your electrostatic discharge Storing Assemblies Always keep assemblies in ESD protective covers These protective co...

Страница 9: ...Multi Band Receiver GNM 181 4TE Init Nav Ant Fail Antenna GNSS L1 L2 5 V GNM 181 C O M 1 2 3 GNM 181 8TE GNM 181 Init Nav Ant Fail XHE SPI 1 3 5 C O M 1 2 3 4 Antenna GNSS L1 L2 5 V 6 Date 25th Februa...

Страница 10: ...red time has not synchronized Fail Ant Nav Init 4 2 Multiref COM 0 The COM 0 interface of the GNM 181 is used for serial communication RS 232 signal level It can also be used as an optional Multiref...

Страница 11: ...edance 50 Ohm Connection Type SMA female Antenna Cable shielded coaxial line Belden H155 Cable lenght deductible up to max 70m Backup Battery Type CR2032 button cell lithium battery The hardware clock...

Страница 12: ...XHE SPI Connectors A1 PPS In A2 PPS Out Pin 1 SCL_Out SPI Clock Pin 2 CS Chip Select Pin 3 MOSI Master Out Slave In Pin 4 MISO Master In Slave Out Pin 5 GND Attention Use this plug only to connect a M...

Страница 13: ...and all accessories and put them aside Check the scope of delivery with the pack ing list to ensure that no parts are missing If any of the listed contents are missing please contact Meinberg Funkuhre...

Страница 14: ...ing materials we use are fully recyclable Material Use for Disposal Cardboard shipping packaging Paper recycling accessories packaging Foil shipping packaging Household waste or recycling depot access...

Страница 15: ...le If you operate your system with only one power supply a second power supply must be installed before removing replacing it to keep your system functioning I O ESI and MRI Slots hot swappable CLK1 C...

Страница 16: ...module carefully out of the guide rail Note that the module is firmly anchored in the connector block of the housing You need a certain amount of force to release the module from this link Once the co...

Страница 17: ...he Antenna location To receive enough satellites select a location that allows an unobstructed view of the sky otherwise there may be problems with the synchronization of the system There should be no...

Страница 18: ...ect the antenna cable Belden H155 to the N Norm connector of the antenna Lead the other end of the cable through the wall into the building GNSS Antenna N Norm female N Norm male Free view to the sky...

Страница 19: ...able to the surge protection socket N Norm male N Norm female Outside wall of the building Outdoor installation Inside a waterproof housing Indoor installation recommended Just after the antenna cable...

Страница 20: ...satellite signal is delayed by the used coaxial cable The connected receiver must compen sate the signal propagation time of the antenna cable therefore you need to enter the length of the antenna cab...

Страница 21: ...d serial port laptop GNSS COM 0 9 pin male SMA female Rb XHE SPI female Serial interface Optional connection G N S S N Norm female Antenna signal Time string Out SPI female BNC female SMA male BNC mal...

Страница 22: ...ding on the design of the system which means whether it is a single reference clock or a system with two installed remote clocks and a changeover card the web interface builds up accordingly This also...

Страница 23: ...st a connected client must send a to receive the time telegram in response Features MRS PPS Plus String If the system has the MRS PPS plus string option the baudrate and framing for the incoming time...

Страница 24: ...ulses of the reference clock The data of the time zone are used from the time zone table see chapter System Display 7 1 3 Enabling the Outputs Optionally the outputs of the reference clock can be set...

Страница 25: ...and GNM By entering the cable length from antenna to receiver the system calculates the delay time and compensates it automatically The default value is 20m and the maximum input value is 500m which...

Страница 26: ...enu a warning message will appear in the browser window Please Note If the GPS receiver is configured to output GPS or TAI timescale instead of UTC the distributed time via NTP isn t based on UTC then...

Страница 27: ...ze all GPS system values this means that all stored satellite data will be deleted Please note that the receiver takes about 15 minutes to read in the information of the satellites again to complete t...

Страница 28: ...e the horizon at its geographic position and can potentially be tracked All these satellites are called to be in view However even some the satellites that are in view may be shielded by buildings mou...

Страница 29: ...system the order of the active and the reserve system is exchanged at every change over For example if the active system switches to the free running mode while the reserve system is operating synchro...

Страница 30: ...8 Technical Specifications GNSS Multiband Antenna 8 Technical Specifications GNSS Multiband Antenna Physical Dimensions IMS GNM181 Setup Guide Date 25th February 2020 27...

Страница 31: ...1 L2 L5 GLONASS G1 G2 G3 Beidou B1 B2 Galileo E1 E5a b plus L band Out of band rejection Freq Band L5 E5 L2 G2 Frequency Gain 1050 MHz 45 dB 1125 MHz 30 dB 1350 MHz 45 dB Freq Band L1 E1 B1 G1 Frequen...

Страница 32: ...BB is equipped with two type N female connectors It has no dedicated input output polarity or prefered mounting orientation Phoenix CN UB 280DC BB Features High RF Performance Multiple Strike Capabili...

Страница 33: ...z Permissible HF power Pmax at VSWR xx 50 ohm system 700 W VSWR 1 1 200 W VSWR Capacity Core Earth typ 1 5 pF asymmetrical shield typ 1 5 pF Surge current resistance conductor ground C1 1 kV 500 A C2...

Страница 34: ...8 Technical Specifications GNSS Multiband Antenna 8 1 1 MBG S PRO Physical Dimensions 67 11 15 8 25 13 4 8 1 2 Installation and Grounding IMS GNM181 Setup Guide Date 25th February 2020 31...