Connecting Data Cables
During a thunderstorm, data transmission lines must not be connected or disconnected (risk of
lightning).

When wiring the devices, the cables must be connected or disconnected in the order of the
arrangement described in the user documentation accompanying the device. Always attach all cables
to the plug during connection and removal. Never pull the cable itself. Pulling the cable can cause
the cables to disconnect from the plug.

Install the cables in way that they do not constitute a hazard (danger of tripping) and are not
damaged, i.e. kinked.

Connecting Power Supply
This equipment is operated at a hazardous voltage. Non-observance of the safety instructions in this
manual may result in serious personal injury or property damage.

Before connecting to the power supply, a grounding cable must be connected to the earth connection
of the device.

Before operation, check that all cables and lines work properly and are undamaged. Pay particular
attention to the facts that the cables do not have kinks or that they are not too short around corners,
and no objects are placed on the cables. Also make sure that all connections are secure.

Faulty shielding or cabling will endanger your health (electrical shock) and may destroy other
equipment.

Ensure that all necessary safety precautions have been taken. Make all connections to a unit before
turning on the power. Observe the safety instructions on the device (see safety symbols).

The metal housing of the device is grounded. It must be ensured that enough air and creepage
distances to neighboring voltage-carrying parts are provided during assembly in the control cabinet
and no short circuits are caused.

In the case of malfunctions or servicing (e.g. in the event of a damaged housing or power cable or
when fluids or foreign objects enter), the current flow can be interrupted. Questions about the
house installation, need to be clarified with your house administration.

The power supply should be connected with a short, low-inductance line.

6

Date: 14th January 2020

FO CONVERTER

Содержание CON/232/FO

Страница 1: ...MANUAL FO CONVERTER Signal Distribution over long Distances 14th January 2020 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...ge 11 2 10 Return of Electrical and Electronic Equipment 12 3 Fiber Optic Converter Overview 13 3 1 LWL Converter Case 13 3 2 CON TTL FO 14 3 2 1 Technical Specifications CON TTL FO 14 3 3 CON FO TTL...

Страница 4: ...rg Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2019 01 13 FO CONVERTE...

Страница 5: ...ay only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an immin...

Страница 6: ...eines elektrischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan blad...

Страница 7: ...used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the...

Страница 8: ...e g Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait unti...

Страница 9: ...properly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure...

Страница 10: ...the mains socket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside th...

Страница 11: ...conductor via the protective earth connection terminal If an external earth connection is provided on the housing it must be connected to the equipotential bonding rail grounding rail The mounting pa...

Страница 12: ...y switching off the devices are not disconnected from the power supply In the event of a fault or service case the devices must be immediately disconnected from all power supplies Follow the steps bel...

Страница 13: ...must not be opened repairs to the device may only be carried out by the manufacturer or by authorized personnel Improper repairs can result in considerable danger to the user electric shock fire haza...

Страница 14: ...ruction Prepare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when wor...

Страница 15: ...he product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country spe...

Страница 16: ...onally included in the scope of supply All converter variants are equipped with a fixing clamp for 35mm DIN mounting rails If necessary each of the output signals can be inverted on request Transmissi...

Страница 17: ...CON FO FO x FO input ST to x 2 3 or 4 FO outputs 3 2 1 Technical Specifications CON TTL FO Input Signal TTL signal via BNC female connector input impedance 10 k Optical Outputs up to four multimode F...

Страница 18: ...one RS422 output DSub 3 3 1 Technical Specifications CON FO TTL optical Input 1 x multimode FO input via ST connector for GI 50 125 m or GI 62 5 125 m gradient fiber optical input level min 3 W Wave l...

Страница 19: ...FO Electrical signals RS 232 input output TxD RxD via male DSub9 connector Pin 2 TxD in Pin 3 RxD out Pin 5 GND or RS 232 input TxD only via male DSub9 connector Pin 2 TxD in Pin 5 GND Optical Signals...

Страница 20: ...Time Code Out BNC 3 5 1 Technical Specifications CON TCM FO Input amplitude modulated IRIG B IEEE1344 or AFNOR signal input insulated by transformer impedance 50 Ohm via female BNC connector Input lev...

Страница 21: ...0 kOhm or RS422 signal via DSub9 male connector pin 5 GND pin 7 IN pin 8 IN or FOS singlemode FO signal via ST connector minimum input level 1 W 30 dBm wave length 1310 nm or FO FO multimode FO signal...

Страница 22: ...L 3 7 1 Technical Specification CON FOS TTL Input Signal one singlemode FO input via ST connector edge triggered for E9 125 m monomode fiber minimum input level 1 W 30dBm wave length 1310 nm Electrica...

Отзывы: